Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

Datasheet 9 pages · 179 KB · EN

The VLMK/Y62.. series is a high‑efficiency power LED in a flat CLCC‑6 SMD package, designed for high‑thermal‑load applications such as automotive lighting, backlighting and traffic signals. It features AllnGaP technology, low thermal resistance, and RoHS‑compliant, lead‑free construction.

The document provides absolute maximum ratings, optical and electrical characteristics, packaging dimensions, soldering profiles, storage recommendations, and regulatory information for the VLMK/Y62.. LEDs.

Read online

Vishay Y62 specifications

Forward current (If)150 mA
Power dissipation (Pmax)450 mW
Junction temperature (Tj)+115 °C
Operating temperature range-40 to +100 °C
Thermal resistance junction/pin (Rthj‑pin)60 K/W
Thermal resistance junction/ambient (Rthj‑amb)110 K/W
Luminous intensity (typical)2800‑5600 mcd
Luminous flux (typical)8800‑14100 lm
Dominant wavelength (typical)583‑624 nm
Forward voltage (typical)1.90‑3.0 V
Optical efficiency29 lm/W
Package thickness0.9 mm
Half‑intensity angle+60°

Source: Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

All Vishay Y62 documents by type

Questions answered in these manuals

What is the maximum forward current for the VLMK/Y62.. LED?

The absolute maximum forward current is 150 mA.

From: Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

What storage humidity is recommended for these LEDs?

Store at less than 60 % relative humidity, preferably in a dry box between 10 °C and 30 °C.

From: Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

What storage temperature range is recommended for the sealed dry bags?

The recommended storage temperature for the sealed dry bags is 10 °C to 30 °C.

From: Vishay VLMK/Y62.. Power SMD LED CLCC-6 Flat Datasheet

How long can the devices be stored in a sealed bag before moisture becomes a problem?

Shelf life in a sealed bag is 12 months at less than 40 °C and less than 90 % relative humidity.