Siemens SITRANS LR 400 Radar Level Transmitter User Manual

Siemens SITRANS LR 400 Radar Level Transmitter User Manual

User Manual 106 pages · 586 KB · ZH

Designed for measuring solids and liquids, the SITRANS LR 400 uses FMCW radar. The manual describes the instrument's structure, system applications, programming, technical specifications, dimensions, and optional cleaning system. It applies to the HART and PROFIBUS versions.

It covers installation, electrical connection, startup, operation, HART parameters, PROFIBUS PA parameters, troubleshooting, maintenance, certificates, and appendices on parameter tables, programming tables, temperature and pressure derating, measuring principle, and communication. This Chinese-language edition is Rev. 5.1, dated 2005. This manual is written in Chinese.

Read online

Siemens LR400 specifications

Extended temperature range-40°C to 149°C
Power supply (AC)120–230 Vac, ±15 %, 6 W (12 VA)
Power supply (DC)24 Vdc, +25 %/‑20 %, 6 W
Maximum measurement distance45 m (147 ft)
Maximum torque0.5–0.6 Nm

Source: Siemens SITRANS LR400 Level Radar User Manual

All Siemens LR400 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What communication protocols does the SITRANS LR400 support?

It supports HART and PROFIBUS‑PA communication.

From: Siemens SITRANS LR400 Level Radar User Manual

What is the maximum measurement distance of the sensor?

The sensor can measure up to 45 m (147 ft).

From: Siemens SITRANS LR400 Level Radar User Manual

What safety requirements must be followed when installing the SITRANS LR 400?

Installation and operation must be performed by qualified personnel following the safety warnings and local regulations to prevent injury or damage.

From: Siemens SITRANS LR 400 User Manual

What power options are available for the SITRANS LR 400?

The device can be powered from 120‑230 V AC (50/60 Hz) or from 24 V DC, each consuming about 6 W.

From: Siemens SITRANS LR 400 User Manual

What power supply options are available for the instrument?

The device can be powered from 120‑230 V AC (15 % tolerance) or from a 24 V DC source with +25/‑20 % tolerance.

From: Siemens SITRANS LR 400 Radar Level Meter Instruction Manual

Which communication protocols does the SITRANS LR 400 support?

It supports HART communication and PROFIBUS PA, and can be used with SIMATIC PDM software.