Start here

Siemens 3VA51 Series Circuit Breaker Operating Instructions
The document is the operating instructions for Siemens 3VA51 series circuit breakers with thermal-magnetic trip units. It identifies model designations 3VA51..-.ED1, 3VA51..-.ED2 and 3VA51..-.ED5 and carries document number A5E03456789110-03, last updated 07 July 2021.
The text includes multilingual danger and notice statements about hazardous voltage, the need to turn off and lock out all power before work, and the requirement that installation and maintenance be performed by qualified personnel. It also shows contents, required tools including M4 x 80 mm, connection, and test sections.
Siemens 3VA specifications
| 3VA1 current range | Up to 160 A |
|---|---|
| 3VA1 rated voltage | 400 V |
| 3VA1 breaking capacity | Up to 70 kA |
| 3VA2 current range | Up to 630 A |
| 3VA2 rated voltage | 400/690 V |
| 3VA2 breaking capacity | Up to 150 kA |
Source: Siemens SENTRON 3VA Molded Case Circuit Breakers Catalog
All Siemens 3VA documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the trip unit ratings for the Siemens QR Circuit Breaker?
The trip unit ratings for the QR Circuit Breaker range from 100A to 250A.
From: Siemens 3VA Molded Case Circuit Breakers Product Catalogue
What are the available ratings for the 3VA Molded Case Circuit Breakers?
Thermal-Magnetic Circuit Breakers are available from 125A - 800A, and Electronic Circuit Breakers are available from 150A - 1000A.
From: Siemens 3VA Molded Case Circuit Breakers Product Catalogue
What is the current range of the 3VA1 molded case circuit breakers?
The 3VA1 molded case circuit breakers are listed up to 160 A.
From: Siemens SENTRON 3VA Molded Case Circuit Breakers Catalog
What voltage and breaking capacity are listed for the 3VA2 breakers?
They are listed at 400/690 V and up to 150 kA.
From: Siemens SENTRON 3VA Molded Case Circuit Breakers Catalog
What type of trip unit does the 3VA51 circuit breaker use?
The document describes a circuit breaker with a thermal-magnetic trip unit.
From: Siemens 3VA51 Series Circuit Breaker Operating Instructions
What must be done before working on the device?
All power supplying the device must be turned off and locked out before work, and all covers must be replaced before power is turned on.
From: Siemens 3VA51 Series Circuit Breaker Operating Instructions