Siemens LU240 Manuals

ManualLib has 2 documents for the Siemens LU240 (Other products): 1 product leaflet, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1User Manual 1

Key facts

Brand
Siemens
Model
LU240
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-11-11

Start here

Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Operating Instructions

Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Operating Instructions

User Manual 60 pages · 582 KB · EN

The SITRANS Probe LU240 is an ultrasonic level transmitter designed for industrial process measurement. This manual provides the information needed to install, connect, and commission the device safely and efficiently.

It includes safety notes, detailed installation and mounting guidance, wiring instructions, commissioning wizards, service and maintenance procedures, technical specifications, HART communication setup, and information on certificates and support.

Read online

Siemens LU240 specifications

Measuring principleUltrasonic level measurement
Measuring range0.2 to 12 m (8 inch to 40 ft), depending on model
Frequency54 kHz
Output4 to 20 mA; HART on certain models
Accuracy3 m version: 10 mm; 6 m and 12 m versions: greater of 0.15% of range or 6 mm, valid from 0.25 m; ±2 mm on ranges 4 m or less
Resolution≤3 mm (0.12 inch)
Non-repeatability≤3 mm (0.12 inch)
Blanking distance0.2 m (0.66 ft)
Update time≤4 s
Beam angle10°
Ambient operating temperature-40 to +80 °C (-40 to +176 °F)
Ambient storage temperature-40 to +85 °C (-40 to +185 °F)
Medium temperature at flange or threads-40 to +85 °C (-40 to +185 °F)
Vessel pressure0.5 bar g (7.25 psi g)
Enclosure materialPBT (Polybutylene Terephthalate)
Degree of protectionType 4X, Type 6, IP66, IP68
Weight0.93 kg (2.1 lb)
Transducer materialETFE or PVDF
Process connection2 inch NPT, R 2 inch, or G 2 inch threaded; 3 inch (80 mm) universal flange
Power supply10.5 to 30 V DC (4 to 20 mA/HART)

Source: Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Product Leaflet

All Siemens LU240 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum measuring range of the SITRANS Probe LU240?

The measuring range is 0.2 to 12 m (8 inch to 40 ft), depending on the model.

From: Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Product Leaflet

Which transducer materials are available?

The transducer is available in ETFE or PVDF.

From: Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Product Leaflet

How is the device activated during commissioning?

Activation is performed in the local commissioning step 7.2.1, where the SITRANS Probe LU240 is turned on and initialized.

From: Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter Operating Instructions