Key facts
- Brand
- Schneider
- Model
- ATV61
- Industry
- Industrial
- Documents
- 9
- Languages
- ZH · JA
- Last added
- 2012-03-21
Start here
Schneider ATV61 Frequency Transformer Guide
The guide describes the ATV61 frequency transformer, covering its power ranges (0.75 – 90 kW at 200‑240 V, up to 2400 kW at higher voltages) and various IP ratings (IP20, IP54, IP23/54). It highlights energy‑saving functions, EMC compliance, and optional customization for different markets.
Installation and operation sections detail wiring, safety interlocks, and the integrated ControllerInside. The document lists supported communication protocols such as Ethernet, Modbus, PROFIBUS DP, DeviceNet and BACnet, and explains how to configure the device for various control systems. This manual is written in Japanese.
Schneider ATV61 specifications
| Default motor frequency | 50 Hz |
|---|---|
| High speed setting | 50 Hz |
| Switching frequency | 2.5 kHz or 12 kHz (depends on rating) |
| Analog input AI1 range | 0‑10 V |
| Analog output AO1 range | 0‑20 mA |
| Logical input LI1 function | Forward (1 running direction) |
All Schneider ATV61 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Disassembly, diagnostics and part numbers, for repair.
Instruction set, parameters and examples for configuring or programming the device.
Questions answered in these manuals
How do I reset the inverter to its factory settings?
Select the "Factory Settings" (FCS-) menu as described on page 217 to restore all parameters to their default values.
What do the safety symbols in the guide indicate?
The symbols warn of potential death hazards, serious injury, or other safety risks that must be observed during installation, operation, or maintenance.
How should the ATV61 be mounted?
The drive can be installed either wall‑mounted or floor‑mounted as shown in the installation diagrams.
What are the recommended installation conditions for the ATV61?
Installation conditions and temperature limits are specified in the sections titled “安装条件与温度条件” and must be followed to ensure proper operation.
How should the DC reactor be installed on the ATV61?
Mount the DC reactor on the top of the inverter or in the cabinet, secure it with the provided screws, and verify the seal between the reactor base and the inverter before wiring.
From: Schneider Electric ATV61 Motor Frequency Transformer Installation Guide
What IP ratings are available for the ATV61?
The ATV61 is offered with IP20, IP54, and IP23/54 ratings depending on the version.