This document is an installation manual for the ATV 61 synchronous and asynchronous motor inverter with a power range of 55kW (75HP) - 800kW (800HP). It covers the installation steps, rated values, dimensions, and weight of the inverter.
Schneider Electric ATV61 is a variable speed drive for synchronous and asynchronous motors. This installation manual covers unpacking, handling, mounting, DC reactor or transformer installation, ratings, dimensions, wiring, optional cards, and electromagnetic compatibility.
It includes safety warnings for qualified personnel, power and control terminal guidance, connection diagrams, and derating information. Programming is covered in a separate programming manual. This manual is written in Chinese.
| Rated power range | 55-90 kW (75-125 HP) at 200-240 V; 90-630 kW (125-900 HP) at 380-480 V; 90-800 kW (125-800 HP) at 500-690 V |
|---|---|
| Line voltage range | 200-240 V, 380-480 V, 500-690 V |
Only qualified personnel may install, adjust, repair, and maintain the drive.
Disconnect all power, lock the breaker open, wait for the charging LED to turn off, then verify DC voltage is below 45 V.
If unused for a long time, power it for at least 5 hours every two years.
Yes, the DC reactor must be used when the drive is connected to a three-phase power circuit.