Analog Devices ADF4158 Manuals

ManualLib has 3 documents for the Analog Devices ADF4158: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADF4158
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-02

Start here

Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati

Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati

Application Note 8 pages · 105 KB · EN

This document describes a method to improve the phase noise (PN) and integer boundary spur (IBS) performance of the ADF4157 and ADF4158 Phase-Locked Loops (PLLs). The improvement is achieved by activating a constant negative bleed current, which adds a constant offset to the charge pump. This offset linearizes the charge pump by moving the operation away from the nonlinear area near the origin, often referred to as the charge pump dead zone. Without this current, sigma-delta quantization noise can fold back in-band, causing excessive noise or spurs, particularly in high-resolution sigma-delta modulators used in these parts.

The note details the effects of bleed current on phase noise and spurs across different charge pump currents and Phase Frequency Detector (PFD) frequencies (12.5 MHz and 25 MHz). It presents measurement results showing that for certain charge pump current values, using negative bleed results in improved integer boundary spurs and phase noise. The document also provides specific loop filter configurations required for different charge pump current settings and PFD frequencies to achieve optimal performance.

Read online

Analog Devices ADF4158 specifications

Applicable ModelsADF4157, ADF4158
Activation RegisterRegister 4, bits DB[24:23]
Minimum Charge Pump Current0.31 mA
Tested PFD Frequencies12.5 MHz, 25 MHz

Source: Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati

All Analog Devices ADF4158 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

When is constant negative bleed current needed for ADF4157 and ADF4158?

It is needed for high resolution sigma-delta modulators (high value of modulus) to prevent sigma-delta quantization noise from folding back in-band and causing excessive noise or spurs.

From: Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati

How is the constant negative bleed activated?

It is activated by setting bits DB[24:23] in Register 4 to the value 0b11.

From: Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati

What is the power supply voltage range for the ADF4158?

The device operates from 2.7 V to 3.3 V for AVDD/DVDD, and the Vp pin can be up to 5.5 V.

From: Analog Devices ADF4158 Datasheet

How are the registers programmed on the ADF4158?

All on‑chip registers are programmed via a simple 3‑wire serial interface (CLK, DATA, LE).

From: Analog Devices ADF4158 Datasheet

What is the operating voltage range of the ADF4158?

The device operates from 2.7 V to 3.3 V.

From: Analog Devices ADF4158 Fractional‑N Frequency Synthesizer Datasheet

What RF frequency range does the ADF4158 support?

It supports RF input frequencies from 0.5 GHz up to 6.1 GHz.