Key facts
- Brand
- Analog Devices
- Model
- ADF4158
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2012-08-02
Start here

Analog Devices AN-1154 Optimizing Phase Noise and Spur Performance of the ADF4157 and ADF4158 PLLs Using Constant Negati
This document describes a method to improve the phase noise (PN) and integer boundary spur (IBS) performance of the ADF4157 and ADF4158 Phase-Locked Loops (PLLs). The improvement is achieved by activating a constant negative bleed current, which adds a constant offset to the charge pump. This offset linearizes the charge pump by moving the operation away from the nonlinear area near the origin, often referred to as the charge pump dead zone. Without this current, sigma-delta quantization noise can fold back in-band, causing excessive noise or spurs, particularly in high-resolution sigma-delta modulators used in these parts.
The note details the effects of bleed current on phase noise and spurs across different charge pump currents and Phase Frequency Detector (PFD) frequencies (12.5 MHz and 25 MHz). It presents measurement results showing that for certain charge pump current values, using negative bleed results in improved integer boundary spurs and phase noise. The document also provides specific loop filter configurations required for different charge pump current settings and PFD frequencies to achieve optimal performance.
Analog Devices ADF4158 specifications
| Applicable Models | ADF4157, ADF4158 |
|---|---|
| Activation Register | Register 4, bits DB[24:23] |
| Minimum Charge Pump Current | 0.31 mA |
| Tested PFD Frequencies | 12.5 MHz, 25 MHz |
All Analog Devices ADF4158 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
When is constant negative bleed current needed for ADF4157 and ADF4158?
It is needed for high resolution sigma-delta modulators (high value of modulus) to prevent sigma-delta quantization noise from folding back in-band and causing excessive noise or spurs.
How is the constant negative bleed activated?
It is activated by setting bits DB[24:23] in Register 4 to the value 0b11.
What is the power supply voltage range for the ADF4158?
The device operates from 2.7 V to 3.3 V for AVDD/DVDD, and the Vp pin can be up to 5.5 V.
How are the registers programmed on the ADF4158?
All on‑chip registers are programmed via a simple 3‑wire serial interface (CLK, DATA, LE).
What is the operating voltage range of the ADF4158?
The device operates from 2.7 V to 3.3 V.
From: Analog Devices ADF4158 Fractional‑N Frequency Synthesizer Datasheet
What RF frequency range does the ADF4158 support?
It supports RF input frequencies from 0.5 GHz up to 6.1 GHz.