Installation guide for WayCon ISZL inductive sensors covering mounting, electrical connection, teach function, and troubleshooting.
This installation guide covers the WayCon ISZL inductive sensors, including unpacking, safety instructions, mounting, electrical connection, accessory cables, teach function, troubleshooting, and EU conformity.
It describes mounting torque limits, connector pin assignments, teach procedures for 1-point, 2-point, and factory reset settings, and possible solutions for common output issues.
| Maximum tightening torque | ISZL-6: 15 Nm (10 Nm within first 5 mm); ISZL-8: 40 Nm; ISZL-24: 100 Nm |
|---|---|
| Connector | M12, male, 5 pins |
| Accessory cable | M12 female, 5 poles, shielded |
No. Inductive sensors do not require any special maintenance or cleaning.
The teach wire must be connected to the positive supply voltage (+V).
Connect the teach wire to +V for more than 10 s; the sensor keeps its previous settings.
It is a precision device used for object detection and providing measuring values as electrical quantities.