WayCon ISZL Inductive Sensors Installation Guide

Installation guide for WayCon ISZL inductive sensors covering mounting, electrical connection, teach function, and troubleshooting.


WayCon ISZL Inductive Sensors Installation Guide - cover page
Brand
Waycon
Category
sensor
Document type
Installation Guide
Language
English
Pages
6
File format
PDF
File size
500 KB
Published
13 November, 2026
Updated
13 November, 2026
MD5 checksum
229A6B395255D3858D06452845A5F736

About this manual

This installation guide covers the WayCon ISZL inductive sensors, including unpacking, safety instructions, mounting, electrical connection, accessory cables, teach function, troubleshooting, and EU conformity.

It describes mounting torque limits, connector pin assignments, teach procedures for 1-point, 2-point, and factory reset settings, and possible solutions for common output issues.

What's inside

  • Introduction
  • General Safety Instructions
  • Maintenance
  • Installation
  • Mounting
  • Influence of mounting situation
  • Electrical Connection
  • Accessory Cable
  • Teach Function
  • Troubleshooting

Specifications

Maximum tightening torqueISZL-6: 15 Nm (10 Nm within first 5 mm); ISZL-8: 40 Nm; ISZL-24: 100 Nm
ConnectorM12, male, 5 pins
Accessory cableM12 female, 5 poles, shielded

Frequently asked questions

Do the ISZL sensors require special maintenance?

No. Inductive sensors do not require any special maintenance or cleaning.

How is the teach function activated?

The teach wire must be connected to the positive supply voltage (+V).

How can a teach procedure be aborted?

Connect the teach wire to +V for more than 10 s; the sensor keeps its previous settings.

What is the intended use of this product?

It is a precision device used for object detection and providing measuring values as electrical quantities.