Installation guide for the WayCon FX series draw wire sensor covering mounting, electrical connection, measurement range and magnetic field notes.
This installation guide for the WayCon FX series draw wire sensor covers first steps, sensor mounting, handling the wire rope, electrical connection, a technical drawing, measurement range notes and magnetic field information.
It also includes the EU declaration of conformity for the FX product series.
| Power supply | 4.9...30 VDC |
|---|---|
| Output signal | 0...9.9 VDC (±0.1) |
| Excitation current | max. 30 mA |
| Warm-up time | 5 min |
| Mounting screws | two M3 pan head machine screws |
| Maximum screw tightening torque | 0.32 Nm |
| Maximum wire rope deviation from vertical | 2° |
The sensor may be mounted on both sides using two M3 pan head machine screws with flat washers under each screw head. Tighten the screws to 0.32 Nm maximum.
The power supply is 4.9...30 VDC. The output signal is 0...9.9 VDC (±0.1) and the excitation current is max. 30 mA.
The rope must be extracted from the sensor vertically, with a maximum variation from the vertical of 2°.
An external magnet with a field strength of 1 mT or greater measured on the side opposite the wire rope exit can have a minor effect on the output, shifting it by several mV. If the magnet moves, a fluctuation in the electrical output will also be noticed.