Instruction manual for the DATASENSOR DS1 series light grid devices covering controls, installation, connections, and technical specifications.
This document serves as an instruction manual for the DATASENSOR DS1 series light grid devices. It provides essential information regarding device controls, including LED indicators on both receiver and emitter units to monitor status and alignment. The guide details proper installation modes, emphasizing parallel alignment of units and mounting on rigid supports, while listing precautions such as avoiding intense light sources and electromagnetic disturbances.
| Power supply | 24 Vdc ± 15% |
|---|---|
| Minimum resolution | 5 mm |
| Measurement precision | ±3.5 mm |
| Response time | 1 ms |
| Operating temperature | 0…+55 °C |
| Housing material | Black electro-painted aluminium |
The yellow LED ON indicates the presence of an object into the controlled area.
It indicates a critical device alignment or functioning close to maximum operating distance.
No, they are not safety devices and must not be used in the safety control of machines.