DATASENSOR DS1 Series Light Grid Instruction Manual

Instruction manual for the DATASENSOR DS1 series light grid devices covering controls, installation, connections, and technical specifications.


DATASENSOR DS1 Series Light Grid Instruction Manual - cover page
Brand
Datasensor
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
244 KB
Published
27 October, 2026
Updated
27 October, 2026
MD5 checksum
15A89FFFB75C75CFED1212F6FB029747

About this manual

This document serves as an instruction manual for the DATASENSOR DS1 series light grid devices. It provides essential information regarding device controls, including LED indicators on both receiver and emitter units to monitor status and alignment. The guide details proper installation modes, emphasizing parallel alignment of units and mounting on rigid supports, while listing precautions such as avoiding intense light sources and electromagnetic disturbances.

What's inside

  • CONTROLS
  • INSTALLATION MODES
  • CONNECTIONS
  • FUNCTIONING AND PERFORMANCES
  • TECHNICAL DATA
  • DIAGNOSTICS
  • SPECIFICATIONS
  • DIMENSIONS

Specifications

Power supply24 Vdc ± 15%
Minimum resolution5 mm
Measurement precision±3.5 mm
Response time1 ms
Operating temperature0…+55 °C
Housing materialBlack electro-painted aluminium

Frequently asked questions

What does the yellow LED on the receiver indicate?

The yellow LED ON indicates the presence of an object into the controlled area.

What does fast blinking of the green receiver LED signify?

It indicates a critical device alignment or functioning close to maximum operating distance.

Are these light grids safety devices for machine control?

No, they are not safety devices and must not be used in the safety control of machines.