Agilent 2200 TapeStation RNA Quality Control Application Note

This Application Note describes the performance comparison and benchmark of the Agilent 2200 TapeStation system with the Agilent 2100 Bioanalyzer system, the industry standard for RNA quality control. The 2200 TapeStation system performs automated analysis of up to 96 samples with approximate analysis time of 1 minute per sample. This Application Note demonstrates the high correlation between RINe generated by the 2200 TapeStation system with the RIN quality assessment of the 2100 Bioanalyzer system. The high reproducibility of RINe achieved with the 2200 TapeStation system in RNA quality assessment is also shown. The 2200 TapeStation system is, therefore, a reliable system for RNA quality control.


Agilent 2200 TapeStation RNA Quality Control Application Note - cover page
Brand
Agilent
Category
Other
Document type
Application Note
Language
English
Pages
8
File format
PDF
File size
949 KB
Published
08 June, 2012
Updated
01 October, 2023
MD5 checksum
AD3C5320AA8DAE75F4878A2130065352

About this manual

This document serves as an application note comparing the performance of the Agilent 2200 TapeStation system with the Agilent 2100 Bioanalyzer system for RNA quality control. It highlights that the 2200 TapeStation performs automated analysis of up to 96 samples with an approximate analysis time of 1 minute per sample using ScreenTape consumables.

The study evaluates the correlation between the RNA Integrity Number (RIN) generated by the 2200 TapeStation and the RIN obtained from the 2100 Bioanalyzer. Results indicate a high correlation (R² values of 0.9878 and 0.9474) and high reproducibility, with intra-assay precision better than 2% to 4% depending on the kit used. The document concludes that the 2200 TapeStation is a reliable system for RNA quality control due to its high throughput, ease of use, and comparable performance to the industry standard.

What's inside

  • Abstract
  • Introduction
  • Equipment
  • Samples
  • Results and discussion
  • Heat degraded RNA analysis
  • RIN and RIN correlation
  • Reproducibility
  • Conclusion
  • References

Specifications

Maximum sample throughputup to 96 samples
Approximate analysis time1 minute per sample
RIN range1 to 10

Frequently asked questions

What is the approximate analysis time per sample on the 2200 TapeStation?

The approximate analysis time is 1 minute per sample.

What is the range of values for the RIN quality metric?

RIN is presented as a value between 1 and 10, where 10 represents the highest quality.

How does the 2200 TapeStation compare to the 2100 Bioanalyzer in terms of precision?

The 2200 TapeStation shows higher precision due to automated sample handling and loading that reduces manual pipetting errors.