Micrel SY10E111 Manuals

ManualLib has 4 documents for the Micrel SY10E111 (Other Electronics): 4 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 4

Key facts

Brand
Micrel
Model
SY10E111
Industry
Electronics
Documents
4
Languages
EN
Last added
2012-05-09

Start here

Micrel SY10E111 SY100E111 ClockWorks Datasheet

Micrel SY10E111 SY100E111 ClockWorks Datasheet

Datasheet 4 pages · 66 KB · EN

The SY10E111 and SY100E111 are low‑skew 1‑to‑9 differential clock drivers for high‑performance ECL systems. They accept a differential or single‑ended input, fan‑out the signal to nine identical differential outputs, and include an enable input that disables all outputs when asserted.

The datasheet lists detailed DC and AC electrical characteristics, propagation delays, skew, setup/hold/release times, input swing limits, and mechanical package dimensions, as well as ordering codes for commercial availability.

Read online

Micrel SY10E111 specifications

VEE output range-4.2 V to -5.5 V
Propagation delay (single‑ended)330 ps – 730 ps
Within‑device skew25 ps – 50 ps
Set‑up time (EN to IN)200 ps
Hold time (IN to EN)0 ps – 200 ps
Release time (EN to IN)100 ps – 300 ps
Minimum input swing (VPP)250 mV
Common‑mode range-1.6 V to -0.4 V
Rise/Fall times275 ps – 600 ps
Package dimensionsDimensions in inches (see drawing)

Source: Micrel SY10E111 SY100E111 ClockWorks Datasheet

All Micrel SY10E111 documents by type

Questions answered in these manuals

What is the VEE output voltage range for the SY10E111?

The SY10E111 provides a VEE output range of –4.2 V to –5.5 V.

From: Micrel SY10E111 SY100E111 ClockWorks Datasheet

How many differential outputs does the SY10E111 provide?

The device fans the signal out to nine identical differential outputs.

From: Micrel SY10E111 SY100E111 ClockWorks Datasheet

What supply voltages are supported by the SY10E111A/L and SY100E111A/L drivers?

Both devices can be powered from either a 5 V or a 3.3 V supply.

From: Micrel SY10E111A/L SY100E111A/L Differential Clock Driver Datasheet

What is the part‑to‑part skew specification?

The part‑to‑part skew is specified as 200 ps.

From: Micrel SY10E111A/L SY100E111A/L Differential Clock Driver Datasheet

What is the typical propagation delay for the differential outputs?

Typical differential propagation delay ranges from about 380 ps to 680 ps depending on the device and voltage.

From: Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

What is the within‑device skew specification?

The within‑device skew is specified as up to 75 ps.

From: Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet