Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

Datasheet 6 pages · 73 KB · EN

The SY10E111AE/LE and SY100E111AE/LE are low‑skew 1‑to‑9 differential clock drivers designed for high‑performance clock distribution. They operate from 5 V or 3.3 V supplies, offer enable control, and provide voltage‑ and temperature‑compensated outputs.

The document lists detailed electrical parameters (output high/low voltages, propagation delays, skew, input currents), pin configurations, package dimensions, and commercial/industrial ordering codes for both the 5 V and 3.3 V versions.

Read online

Micrel SY10E111AE specifications

Power‑supply range (5 V version)4.2 V to 5.5 V
Power‑supply range (3.3 V version)3.0 V to 3.8 V
Typical output HIGH voltage (5 V, SY10E111AE)≈ 3.92 V
Typical output LOW voltage (5 V, SY10E111AE)≈ 3.05 V
Within‑device skew≤ 75 ps
Propagation delay (differential, 5 V)380 ps to 680 ps

Source: Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

All Micrel SY10E111AE documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the typical propagation delay for the differential outputs?

Typical differential propagation delay ranges from about 380 ps to 680 ps depending on the device and voltage.

From: Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

What is the within‑device skew specification?

The within‑device skew is specified as up to 75 ps.

From: Micrel SY10E111AE/LE and SY100E111AE/LE ClockWorks Datasheet

How many differential outputs does the SY10E111AE/LE provide?

The device fans out one input signal to nine identical differential outputs.

From: Micrel SY10E111AE/LE SY100E111AE/LE Clock Driver Datasheet

What is the required termination for the differential outputs?

Both sides of each differential output must be terminated into 50 Ω, even if only one side is used.

From: Micrel SY10E111AE/LE SY100E111AE/LE Clock Driver Datasheet