SMC LECSS2-T Series Servo Motor Controller User Manual

This series of products are AC servo motor controllers with the following features: 1. Support SSCNETⅢ/H communication protocol 2. Built-in PID control 3. Support absolute position detection 4. Support electronic gear and cam functions 5. Support multiple home return modes 6. Support multiple protection functions


SMC LECSS2-T Series Servo Motor Controller User Manual - cover page
Brand
SMC
Category
Servo motor
Document type
User Manual
Language
Japanese
Pages
63
File format
PDF
File size
2.7 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
F918C17077A69DC24E3A9768D6FF2FA4

About this manual

This is the simplified user manual (document No. LEC-OML0001) for the SMC LECSS2-T□ Series servo motor controller, used with SMC electric actuators such as the LEF and connected over an SSCNET III cable to a positioning unit or motion controller. It explains the equipment needed for start-up, the steps before operation, and how the controller is configured.

The manual covers power supply, SSCNET III cable and I/O signal wiring, axis number setting, the list of parameters set on the controller side, parameter setting with the MR Configurator2 setup software (selecting MR-J4-□), parameter setting on the PLC side, return to origin, positioning operation and a fault/alarm list including power-on faults. This first edition is dated 2016. This manual is written in Japanese.

What's inside

  • Configuration
  • Steps before operation (flow chart)
  • Wiring
  • Axis number setting
  • Parameter list set on the controller
  • Parameter setting with the MR Configurator2 setup software
  • Parameter setting (PLC side)
  • Return to origin (PLC)
  • Positioning operation (PLC)
  • Fault list (alarms, warnings, power connection faults)

Specifications

Main circuit / control power supplyAC200 V
Communication cycle (up to 8 axes)0.222 ms
Communication cycle (up to 16 axes)0.444 ms
Communication cycle (up to 32 axes)0.888 ms
Motor cableLE-CSM-□
Encoder cableLE-CSE-□
SSCNET III cableLE-CSS-□
I/O connectorLE-CSNS

Frequently asked questions

What power supply does the main circuit and control circuit need?

Both the main circuit power supply and the control power supply are AC200 V, and the manual asks you to confirm their wiring.

Which model do I select in the MR Configurator2 setup software for the LECSS2-T?

You select MR-J4-□, by choosing File, then New, then Model.

What should I check if the display shows Ab?

Ab means initial communication with the servo system controller is not complete; check whether the control axis invalid switch (SW2-2) is ON and turn it off.

What causes an AA display?

An AA display can appear when the SSCNET III cable is broken; the manual also lists the controller power being off as a cause.