This manual introduces the use, safety and other information of the ZSE20(F) / ISE20 high precision digital pressure switch.
This document is the instruction manual for the SMC ZSE20(F)/ISE20 high precision digital pressure switch. It states that the intended use is to measure, monitor and display pressure and provide an output signal.
The manual includes safety standards, general and connection specifications, cable specifications, part names and functions, and installation and mounting instructions. This manual is written in Spanish.
| Fluid | Air, non-corrosive gas and non-flammable gas |
|---|---|
| Pressure range (ZSE20 vacuum) | 0.0 to -101.0 kPa |
| Pressure range (ZSE20F combined) | -100.0 to 100.0 kPa |
| Pressure range (ISE20 positive) | -0.100 to 1.000 MPa |
| Display/regulation range (ZSE20) | 10.0 to -105.0 kPa |
| Display/regulation range (ZSE20F) | -105.0 to 105.0 kPa |
| Display/regulation range (ISE20) | -0.105 to 1.050 MPa |
| Minimum setting unit | 0.1 kPa or 0.001 MPa |
| Test pressure | 500 kPa or 1.5 MPa |
| Supply voltage | 12 to 24 VDC (±10%) |
| Current consumption | 25 mA maximum |
| Indicator accuracy | ±2% of full scale ±1 digit |
| Repeatability | ±0.2% of full scale ±1 digit |
| Temperature characteristics | ±2% of full scale (25 °C standard) |
| Output type | NPN or PNP open collector, 1 output |
| Maximum load current | 80 mA |
| Maximum applied voltage | 28 V (NPN output) |
| Internal voltage drop | 1 V maximum at 80 mA |
| Response time | 1.5 ms maximum |
| Hysteresis mode | Variable from 0 |
| Short-circuit protection | Provided |
| Display | LCD with 3 display fields |
| Display color | Main display red/green; secondary display orange |
| Digital filter | 0, 10, 50, 100, 500, 1000, 5000 ms |
| Ingress protection | IP40 |
| Dielectric strength | 1000 VAC for 1 minute |
| Insulation resistance | 50 MΩ minimum |
| Operating temperature | -5 to 50 °C |
| Storage temperature | -10 to 60 °C |
| Humidity | 35 to 85% RH |
| Cable length | 2 m |
| Conductor area | 0.15 mm² (AWG26) |
| Insulation diameter | 1.0 mm |
| Cable colors | Brown, blue, black (3 wires) |
| Cable jacket diameter | φ3.4 |
| Body weight | 22 to 34 g depending on connection |
| Cable and connector weight | +35 g |
| Mounting screw torque | 0.5 ±0.05 N·m |
| Panel adapter rotation | 90 degrees |
| Display units | MPa, kPa, kgf/cm², bar, psi, inHg, mmHg |
| Connection sizes | M5, R1/8, NPT 1/8 and metric/inch tube sizes |
It is intended to measure, monitor and display pressure and provide an output signal.
12 to 24 VDC (±10%), with maximum ripple of 10% (p-p).
Air, non-corrosive gas and non-flammable gas.
IP40.