This instruction manual is about the operation of the S65-PA-5-V09 color sensor
This manual provides step-by-step instructions for installing and configuring the DATASENSOR S65-PA-5-V09 colour sensor. It details how to mount the sensor using M4 screws, set operating modes (C or C+I), adjust tolerance levels, and configure delay settings using pushbuttons or RS485 serial commands. Technical specifications include power requirements, output types, operating temperature, and environmental protection ratings. Remote control via RS485 is supported with ASCII commands for channel, tolerance, and delay configuration.
| Power Supply | 10 … 30 Vdc |
|---|---|
| Consumption | 60 mA max. @ 24Vdc |
| Outputs | 3 PNP or NPN outputs 30 Vdc max. (short-circuit protection) |
| Operating Temperature | -10 … 55 °C |
| Storage Temperature | -20 … 70 °C |
| Operating Distance | 20 mm (typical) |
| Minimum Spot Dimension | ∅ 4 mm |
| Response Time | 335us |
| Switching Frequency | 1.5 KHz |
| Housing Material | ABS |
| Lens Material | Glass |
| Mechanical Protection | IP67 |
| Weight | 100 g. max. |
Press the SET pushbutton to enter the setting mode, then use the SEL pushbutton to select C (colour) or C+I (colour + intensity) mode.
The maximum tightening torque for the mounting screws is 1 Nm.
The sensor operates within a temperature range of -10 to 55 °C.
The maximum output current is 100 mA.