Schneider ATV 31H Variable Speed Drive Installation Guide

This document is about the installation and programming manual of ATV 31H variable speed drives


Schneider ATV 31H Variable Speed Drive Installation Guide - cover page
Brand
Schneider
Document type
Installation Guide
Language
English
Pages
100
File format
PDF
File size
1.2 MB
Published
17 November, 2011
Updated
30 September, 2023
Model
ATV 31H
MD5 checksum
C5D93927C66BEE88B0452214C95D3A05

About this manual

This guide provides step‑by‑step instructions for installing, mounting, and wiring the Schneider ATV 31H variable speed drive. It covers safety precautions, required clearances, and EMC compliance to ensure a reliable and safe installation.

The document also includes detailed technical data such as supply voltage ranges, switching frequency limits, dimension tables, weight specifications, and derating curves. Configuration and parameter settings, fault codes, and communication options are described for proper commissioning and troubleshooting.

What's inside

  • Drive references
  • Mounting
  • Wiring
  • Mounting dimensions and weights
  • EMC mounting plate
  • Configuration/Settings table
  • Fault menu
  • Communication menu

Specifications

Single‑phase supply voltage200–240 V, 50/60 Hz
Three‑phase supply voltage200–240 V, 50/60 Hz
Switching frequency range2 kHz – 16 kHz
Maximum ambient temperature for ratings50 °C
Maximum current at 200 V (H018M2)4.8 A
Dimensions (Size 1)72 mm × 145 mm × 120 mm
Minimum front free space for cooling10 mm

Frequently asked questions

How much free space is required in front of the unit for proper cooling?

A minimum of 10 mm of free space in front of the unit is required to allow airflow.

What mounting configuration is recommended when IP20 protection is sufficient?

When IP20 protection is adequate, the protective cover on the top of the drive should be removed.

At what switching frequency does the drive start to reduce its frequency to protect against overheating?

The drive reduces the switching frequency when it exceeds 4 kHz.

Download PDF (1.2 MB)

More Schneider Manuals