Schneider Electric ATV 31H Error SCF: Motor short-circuit

Variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeSCF

Motor short-circuit results from short-circuit or earthing at the drive output or significant earth leakage current when multiple motors are connected in parallel. The manual's first action is: “Check the cables connecting the drive to the motor, and the motor insulation.”

Model
Schneider Electric ATV 31H
Display shows
Motor short-circuit (SCF)
Type
Fault code
Source
Manual p. 92

What SCF means

Motor short-circuit p. 92

Common causes

  • Short-circuit or earthing at the drive output p. 92
  • Significant earth leakage current at the drive output when several motors are connected in parallel p. 92

What to do

  1. Check the cables connecting the drive to the motor, and the motor insulation. p. 92
  2. Reduce the switching frequency. p. 92
  3. Connect chokes in series with the motor. p. 92

Before you service the product, read the safety instructions in the manual p. 56.

If SCF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about SCF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.