Overvoltage during deceleration happens when braking is too sudden or driving load is excessive. The manual's first action is: “Increase the deceleration time. Install a braking resistor if necessary. Activate the brA function (page 44) if it is compatible with the application.”
- Model
- Schneider Electric ATV 31H
- Display shows
- Overvoltage during deceleration (DBF)
- Type
- Fault code
- Source
- Manual p. 93
What DBF means
Overvoltage during deceleration p. 93
Common causes
- Braking too sudden or driving load p. 93
What to do
- Increase the deceleration time. Install a braking resistor if necessary. Activate the brA function (page 44) if it is compatible with the application. p. 93
Before you service the product, read the safety instructions in the manual p. 56.
If DBF is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about DBF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.
