Agilent manuals, page 77
Agilent 710 Series ICP-OES Specifications Manual
Agilent 710 Series ICP-OES spectrometers are manufactured according to a quality management system certified to ISO 9001. The 710 and 715 ICP-OES systems are compact, bench-mounted simultaneous Inductively Coupled Plasma Optical Emission Spectrometers (ICP-OES) with full PC control and compatible accessories. They feature an innovative megapixel CCD detector designed specifically for ICP-OES and provide complete wavelength coverage from 177–785 nm. Agilent ICP-OES systems are available in either axially (710) or radially (715) viewed configurations and include a free-running, air-cooled 40 MHz RF generator, purged echelle polychromator, and full PC control of plasma viewing position and plasma gas flows. The fully web-integrated ICP Expert II software uses Agilent’s worksheet concept for ease of use, rapid operator training, and commonality with Agilent Atomic Absorption products.
Agilent 720/730 Series ICP-OES Specifications Manual
Product Leaflet 8 pages · 105 KB · ENThe Agilent 720/730 Series ICP-OES specifications manual provides detailed technical data, performance metrics, and accessory options for the bench‑mounted…
Agilent 7696A Sample Prep WorkBench Specification Guide
Agilent 7696A is Agilent's laboratory automation liquid handling system, which supports GC, LC, GC/MS, LC/MS automatic sample preparation
Agilent Cary 600 Series FTIR guaranteed specifications Manual
Agilent 660/670/680 Series FTIR is the world’s best FTIR. It has the following features: a 38 mm dynamically aligned, 60° mechanical bearing Michelson interferometer, covering the widest spectral range down to 20 cm-1, maximum resolution better than 0.075 cm-1, revolutionary air-cooled source, delivering more than 50 mW of power. The instrument can be upgraded to 670 or 680 FTIR, providing you with maximum flexibility as your FTIR needs change.
Agilent Cary 640 FTIR guaranteed specifications Manual
Agilent 640 FTIR is a high-performance spectrometer that is suitable for QA/QC or method development applications where higher performance is required. It has a range of unique, easy-to-use hardware and software features that allow even novice users to quickly become productive.
Agilent Cary 100/300 Series UV-Vis typical specifications Manual
The document provides an overview of the design and performance specifications of the Agilent Cary 100/300 Series UV-Vis spectrophotometers. The series features a double beam, dual chopper, ratio recording, Czerny-Turner 0.278 m monochromator structure centrally controlled by a computer. It has a high light throughput optical system with all reflective optical design and high-speed accurate scanning capabilities. The spectrophotometers also come with an optional centrally-controlled accessory system. They are equipped with a high-performance R928 photomultiplier tube, a tungsten-halogen visible source with a quartz window, and a deuterium arc ultraviolet source. The products in the Cary 100/300 Series are manufactured according to a quality management system certified to ISO 9001. The specifications provided in the document are based on the average results of the final acceptance tests performed in the factory using a sample of over two thousand Cary 100 and 300 UV-Vis instruments. These specifications are not guaranteed, and guaranteed specifications are listed in a separate publication based on the ±4 sigma statistical confidence level.
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR guaranteed specifications Manual
Agilent Cary 4000/5000/6000i series UV-Vis-NIR spectrophotometers are double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometers (Agilent Cary 4000 is UV-Vis only)
Agilent Cary 100/300 Series UV-Vis guaranteed specifications Manual
The document provides an overview of the design and performance specifications of the Agilent Cary 100/300 Series UV-Vis spectrophotometers. These spectrophotometers feature a double beam, dual chopper, ratio recording, Czerny-Turner 0.278 m monochromator centrally controlled by a PC. The Cary 300 model has double dispersion, while the Cary 100 model has single dispersion. They both have a high light throughput optical system with all reflective optical design and high-speed accurate scanning. The spectrophotometers can be optionally equipped with a centrally controlled accessory system. They utilize a high-performance R928 photomultiplier tube, a tungsten halogen visible source with a quartz window, and a deuterium arc ultraviolet source. The Agilent Cary 100/300 Series UV-Vis spectrophotometers are manufactured according to a quality management system certified to ISO 9001. The guaranteed specifications are based on the ±4 sigma statistical confidence level of the final acceptance tests performed at the factory. Typical specifications are not reported in this document.
Agilent Consumables Supplies Required for Repair Manual
This file introduces the Consumables and Supplies Required for Repair (repair required consumables and spare parts) option included in Agilent Advantage Bronze, Silver and Gold plans. This option covers the costs of all consumables or supplies required by your service engineer to diagnose instrument problems or affect the repair of your instrument systems. And, since all Advantage plans also cover travel, labor, and repair parts, you can be confident that you’re fully covered for all costs of instrument repair. Best of all, you’ll get genuine Agilent parts, consumables, and supplies, no matter the number of visits or quantity of consumable items required to return your system to normal operations. In as little as one visit, plans that include consumables and supplies coverage can easily pay for the price uplift from a service plan without this feature.
Agilent Recommended PC Specifications for OpenLAB CDS Workstation Manual
This document provides recommended specifications for the OpenLAB CDS Workstation and ChemStation Workstation PC Bundles. The recommended specifications include requirements for processor, RAM, hard disk, display, and operating system.
Agilent French version - Cary 60 UV-Vis Specifications Manual
The Agilent Cary 60 UV-Visible spectrophotometer is a high-performance, accurate, and flexible spectrophotometer equipped with a full-spectrum single pulsed xenon lamp for measurements in the 190-1100nm wavelength range.
agilent 750D Heater/Circulator handbook
The 750D Heater/Circulator is a benchtop, all-purpose, precision heater/circulator that is designed expressly for use with Agilent dissolution and drug release apparatus. It monitors and self regulates water bath temperature using a remote thermistor which is placed in the water bath.
agilent 810 Peristaltic Pump handbook
Agilent 810 is a flexible, bi-directional peristaltic pump with 16-channel maximum capacity for sample transfer in all dissolution sampling systems, and an 8-roller design for smooth flow.
agilent 808 Filter Changer handbook
The 808 Filter Changer is designed to filter dissolution samples from six, seven or eight lines simultaneously and can store up to 200 filters at a time. The Agilent 808 must be used in conjunction with the 806 Syringe Pump and can easily be added to an existing configuration that includes the 8000 Dissolution Sampling Station.
agilent Rotating Bottle Apparatus handbook
The Rotating Bottle Apparatus is designed for release-rate testing of most dosage forms. It consists of a rotating shaft, a water bath, and a programmable rotation speed. The rotating shaft holds the bottles in the water bath and can rotate at a speed that can be adjusted according to the need. The device has no evaporative loss and is suitable for long-term drug release performance testing.