Agilent manuals, page 75
Agilent 225-MS Ion Trap Mass Spectrometer Manual
Specification sheet of 225-MS ion trap mass spectrometer. The instrument has a mass range of 10-650 Da and can store up to five ranges of ions and eject matrix and column bleed.
Agilent 920-LC Specification sheet Manual
The Varian 920-LC analytical high performance liquid chromatograph is an integrated, pre-configured, pre-plumbed system that can be controlled by Varian Galaxie™ Chromatography Software on a single computer, or through a fully networked client and acquisition server. The low pressure quaternary gradient reciprocating dual piston pump with built-in Degasser, or isocratic pump delivers consistent, reliable solvent flow throughout the HPLC system. The autosampler direct injection method ensures carryover of less than 0.01% and has optional sample cooling. A column heater holds up to two columns from 4.6 to 13 mm ID and 50 to 300 mm length. Options of a UV-Vis or photodiode array (PDA) detector provide high sensitivity and low noise. Fluorescence, refractive index (RI) and evaporative light scattering (ELS) detectors with a cooling option can also be added for the analysis of non UV-Vis absorbing compounds.
Agilent Cary 50 UV-Vis spectrophotometer: Guaranteed Specifications Manual
This document is a specification sheet for Varian Cary® 50 UV-Vis spectrophotometer. It mainly introduces the design overview, spectral range, wavelength range, resolution, spectral accuracy and other characteristics of the product.
Agilent Cary 50 UV-Vis Spectrophotometer: Typical Specifications Manual
This document provides a detailed overview of the technical specifications of the Varian Cary 50 UV-Vis spectrophotometer.
Agilent SPECIFICATION FOR A 7.0 TESLA/400MM ROOM TEMPERATURE BORE MAGNET SYSTEM Manual
This document is a specification for a 7.0 TESLA/400MM room temperature bore magnet system. The system is a complete superconducting magnet system intended primarily for research studies on the clinical/biological applications of NMR imaging (MRI) and NMR spectroscopy (MRS). The system consists of a highly homogeneous superconducting magnet (300MHz 1P, 7.05 Tesla) housed in a horizontal room temperature bore (400mm), low-loss helium cryostat. Field shimming is normally accomplished using both superconducting and room temperature shim coils. For imaging applications, X, Y, and Z gradient coils can also be provided with the system. Normally, the room temperature shims and gradients are mounted on independent non-conducting formers and are positioned.
Agilent SPECIFICATIONS FOR A 4.7 TESLA/400MM ACTIVELY SHIELDED MAGNET SYSTEM Manual
This document introduces the specifications of a 4.7 Tesla/400mm actively shielded magnet system.
Agilent TECHNICAL SPECIFICATIONS FOR AN MRBR 9.4 TESLA 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM Manual
This document describes the technical specifications of an MRBR 9.4 Tesla / 160mm actively shielded room temperature bore magnet system prepared by Magnex Scientific Limited.
Agilent SPECIFICATIONS FOR A 4.7 TESLA/310MM BORE ACTIVELY SHIELDED MAGNET SYSTEM Manual
This is a technical specification of the MRBR 4.7/310/AS superconducting magnet system, which introduces the composition, features and performance parameters of the system
Agilent SPECIFICATIONS FOR A 7.0 TESLA/210MM BORE ACTIVELY SHIELDED MAGNET SYSTEM Manual
This document is a technical specification for a magnet system. It mainly introduces the composition, features and performance of the magnet system.
Agilent PRELIMINARY TECHNICAL SPECIFICATION FOR A 7.0 TESLA 400MM ACTIVELY SHIELDED MAGNET SYSTEM Manual
This is a technical specification for a 7.0 Tesla / 400mm actively shielded magnet system intended primarily for research studies on the clinical/biological applications of NMR imaging (MRI) and NMR spectroscopy (MRS).
Agilent SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM Manual
This document is a technical specification that introduces the features and characteristics of the MRBR 9.4 TESLA/310MM/AS superconducting cryo-cooled magnet system by Magnex Scientific Limited.
Agilent SPECIFICATIONS FOR AN MRBR 4.7 TESLA 160MM ACTIVELY SHIELDED MAGNET SYSTEM Manual
This document introduces the technical specifications of the MRBR 4.7 Tesla/160mm actively shielded room temperature bore magnet system
Agilent TECHNICAL SPECIFICATIONS FOR AN MRBR 7.0 TESLA/160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM Manual
This document introduces the technical specifications of MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM.
Agilent TECHNICAL SPECIFICATIONS FOR A WATER COOLED ACTIVELY SHIELDED GRADIENT SYSTEM WITH RT SHIM SET Manual(3)
This document describes a water-cooled actively shielded gradient system with an RT shim set, manufactured by Magnex Scientific Limited. The system features optimized X, Y, and Z coil configurations, suitable for ≥210mm room temperature bore superconducting magnets and gradient systems.
Agilent PRELIMINARY SPECIFICATIONS FOR AN MRBR 7.0 TESLA 210MM ACTIVELY SHIELDED MAGNET SYSTEM Manual
This is a technical specification document, mainly introducing the basic information of MRBR 7.0/210/ASZ system, including superconducting magnet, superconducting magnet system components and standard components