Agilent manuals, page 196
Agilent 7700s ICP-MS Semiconductor Analysis Application Note
Application Note 8 pages · 774 KB · ENThis application note details the basic performance of the Agilent 7700s ICP-MS for analyzing semiconductor samples, highlighting its sensitivity…
Agilent 1290 Infinity LC Rapid Gradient Elevated Temperature UHPLC of Flavonoids Application Note
Application Note 8 pages · 796 KB · ENThis application note describes the analysis of flavonoids in citrus fruit using an Agilent 1290 Infinity LC System with ZORBAX RRHD columns, demonstrating…
Agilent 1220 Infinity LC System Amoxicillin Impurity Analysis Application Note
Application Note 8 pages · 462 KB · ENThis application note details the analysis of amoxicillin and five impurities using the Agilent 1220 Infinity LC System, demonstrating detection down to 0.01%.
Agilent 1290 Infinity LC System Application Note for Amino Acid Analysis
Application Note 4 pages · 693 KB · ENThis application note describes the fast and sensitive analysis of water-soluble amino acids in food products using automated precolumn derivatization with…
Agilent 1290 Infinity LC System PAH Method Development Application Note
Application Note 1 pages · 2.4 MB · ENThis application note describes a high-throughput method for separating 16 PAHs using the Agilent 1290 Infinity LC system and ZORBAX Eclipse PAH column in…
Agilent Automated Preparation of Simulated Distillation Standards Samples for ASTM Methods D2887 D7213 D7398 D6352 using the 7693A System with Easy SamplePrep Software Application Note
Application Note 8 pages · 244 KB · ENThis application note describes automated preparation of hydrocarbon calibration standards and samples for ASTM simulated distillation methods using the…
Agilent Cary 50 Microvolume Applications in Biochemistry and Molecular Biology
Application Note 3 pages · 245 KB · ENApplication note detailing the use of the Agilent Cary 50 spectrophotometer for microvolume analysis of DNA, RNA, proteins, and kinetics using the Hellma…
Agilent Cary 50 Spectrophotometer Application Note: Measuring Relative % Reflectance of Small Samples
Application Note 3 pages · 139 KB · ENThis application note describes using the Agilent Cary 50 spectrophotometer with a Hellma TrayCell to measure relative percent reflectance (%R) on small…
Agilent Photodegredation of Protein Light Harvesting Complexes In 4ul Microvolume Samples Application Note
Application Note 2 pages · 314 KB · ENThis application note demonstrates measuring photodegradation in protein light harvesting complexes using the Agilent Cary 6000i spectrophotometer and…
Agilent Cary 50/300/4000 Series Microvolume Measurement Application Note
Application Note 5 pages · 198 KB · ENThis application note investigates the precision and reproducibility of Agilent Cary 50, 300, and 4000 series spectrophotometers for microvolume DNA…
Agilent Fluorescence in Microvolumes: 30uL Volumes in 384 Well Microplates Application Note
Application Note 3 pages · 135 KB · ENThis application note describes analyzing 30uL samples in 384 well microplates using the Cary Eclipse spectrofluorimeter.
Agilent Eclipse Fluorimeter 5uL Microcell Application Note
Application Note 3 pages · 156 KB · ENThis application note describes the Starna Scientific 5uL microcell designed for the Agilent Cary Eclipse Fluorimeter, demonstrating its ability to perform…
Agilent Software-Assisted Identification of Metabolites Application Note
Agilent Aflatoxin Determination Application Note for 1290/1260 LC Systems
Application Note 4 pages · 548 KB · ENThis application note describes the determination of aflatoxins using Agilent 1290 and 1260 Infinity LC systems with ZORBAX RRHT columns and post-column…
Agilent 1290 Infinity LC System Application Note
Application Note 8 pages · 780 KB · ENThis application note demonstrates how optimizing flow rate and gradient time increases peak capacity for peptide analysis using the Agilent 1290 Infinity…
