Agilent manuals, page 133
Agilent Technologies 6890/5973 GC/MSD System Application Note
This report describes an analysis method using GC/MS SIM technology to determine extractable amines in textiles and other materials, the method provides flexibility in low-level detection and can be used to analyze environmental samples associated with contamination monitoring of colorization process waste streams.
Agilent The APEX ProSep 800 XT Plus Precolumn Separation Inlet: Advantages of a Chromatographic Zone as GC Inlet System
ProSep is a novel gas chromatography separation method that eliminates solvent before the column by installing a pre-separation column at the injection point, thereby avoiding the interference of solvent and improving the sensitivity. It shows excellent performance in a wide range of applications.
Agilent Technologies Large-Volume Injection for Gas Chromatography Using COC-SVE Application
This application note describes large-volume injection (LVI) with a cool on-column (COC) inlet and solvent vapor exit (SVE) kit and is illustrated with examples of straight-chain hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), and semivolatiles.
Agilent Technologies Multiple Headspace Extraction-Capillary Gas Chromatography for the Quantitative Determination of Volatiles in Solid Matrices Application
A multiple headspace extraction capillary gas chromatographic (MHE-CGC) method for the quantitative, accurate, and rapid determination of volatile components in solids such as polymers, resins, and activated carbon has been developed. A five-step MHE determination was performed using the Agilent 7694 headspace sampler and a 5890 Series II GC with EPC. A Microsoft® Excel spreadsheet was used to quickly perform the required calculations. Details of the procedure and implications affecting the analysis of polymeric materials are discussed.
Agilent Ambient Headspace Analysis with the Agilent 7683 Automatic Liquid Sampler Data sheet
This document describes the application of Agilent 7683 automatic liquid sampler (ALS). ALS can be used to perform thermostatted headspace analysis and ambient headspace analysis. The benefits of using ALS include increased sample throughput, reduced equipment cost, and simplified operation.
Agilent Technologies Using a Mass Selective Chemical Sensor to Help Identify Unknowns Application
Agilent Technologies has developed a chemical sensor, the Agilent 4440A, which can rapidly distinguish among similar products with volatile constituents. The instrument consists of a modified Agilent headspace autosampler coupled directly to a modified Agilent mass selective detector. Unlike headspace gas chromatography with mass selective detection (HS/GC/MS), this system has no GC, and there is virtually no separation of the volatile constituents. Instead, the headspace volatiles are transferred directly to the mass selective sensor, which typically gives rise to a single broad peak composed of all the volatile constituents in the sample. Because the mass spectra of all these compounds are also overlaid, multivariate analysis and pattern recognition software are used to classify the samples. The advantages of this system over conventional HS/GC or HS/GC/MS are its speed and ease of use. Samples can be analyzed every 2 to 6 minutes, depending upon the amount of headspace equilibration time required, and operator training takes less than an hour. This application note discusses how the 4440A chemical sensor has been used to discriminate among various products. Most interestingly, this application note also shows how to use the information from the 4440A chemical sensor to identify unknowns.
Agilent Retention Time Locking Using USP 467 Standard Sample Automated Headspace Sampling
This application note describes how to use Agilent Technologies’ retention time locking (RTL) software to match the retention time of an automated headspace GC system with that of a standard sample. RTL software allows the retention times of any Agilent 6890 Series or Agilent 6850 gas chromatograph (GC) system to be matched precisely to those of any other, as long as the systems are equipped with electronic pneumatics control. The results from different systems are virtually identical, independent of inlet, detector, operator, or location.
Agilent Fast GC: Comparison of the Agilent 6890 Plus GC with Oven Insert the Agilent 6850 Series GC
This article discusses how to increase the maximum achievable oven program rate by reducing the GC oven volume to shorten the GC analysis time. Comparisons were made between the Agilent 6890 Plus GC with Oven Insert and the Agilent 6850 Series GC, showing a dramatic increase in oven program rate with the use of the 6890 GC oven insert.
Agilent Enhanced Reliability of Forensic Drug Testing Using Retention Time Locking
Retention time locking (RTL) is used to lock retention times when transferring methods from chromatographic instrument to chromatographic instrument, column to column, and detector to detector. This article discusses the application of RTL in forensic drug testing, specifically for the analysis of cocaine and its derivatives. The study shows that by locking the retention times of a derivatized cocaine standard, it is possible to achieve consistent retention times across different instruments and during routine maintenance procedures.
Agilent Empirical Formula Determinations Compound-Independent Calibration Using a GC-AED System
Empirical Formula Determinations and Compound-Independent Calibration Using a GC-AED System
Agilent Comparison of Denaturing non-Denaturing Mobile Phases in SEC: ZORBAX GF-250 /- GuCl
This document introduces a protein separation method based on high-performance liquid chromatography. The method uses non-covalent affinity chromatography columns and polyacrylamide gel chromatography columns, which can effectively separate proteins of different molecular weights.
Agilent Technologies J W Capillary Columns for GC/MS Trace Analysis from Agilent Technologies Technical Note(1)(1)
This document introduces Agilent's J&W low bleed columns, including product features, characteristics and advantages.
Agilent Technologies J W Capillary Columns for GC/MS Trace Analysis from Agilent Technologies Technical Note(1)
Agilent low bleed GC/MS columns are specifically designed to overcome the challenges of low level trace analysis. These columns have low bleed and high temperature performance, providing more accurate results without compromising analysis time.
Agilent Technologies Utilizing the Web with Agilent Network Data Systems Technical Note
This technical note describes in detail how Agilent software makes it simple to take advan- tage of the Web and client/server tech- nology.
Agilent Screening Environmental Samples Using UV-Vis Spectroscopy
This paper introduces the method of using UV-Vis spectroscopy to screen environmental samples.