Agilent J&W Capillary Columns for GC/MS Technical Note

Agilent low bleed GC/MS columns are specifically designed to overcome the challenges of low level trace analysis. These columns have low bleed and high temperature performance, providing more accurate results without compromising analysis time.


Agilent J&W Capillary Columns for GC/MS Technical Note - cover page
Brand
Agilent
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
297 KB
Published
03 July, 2012
Updated
30 September, 2023
MD5 checksum
8C280A65895E199010A30EB393DA190E

About this manual

This document introduces a new generation of thermally resistant, low bleed capillary columns from Agilent Technologies (J&W Scientific). These columns are specifically engineered to meet the demands of modern benchtop mass spectrometers and ion traps by reducing background noise and improving spectral purity at elevated temperatures.

The text details four specific column options: DB-5ms, DB-XLB, DB-35ms, and DB-17ms. It explains that these columns utilize unique polymer chemistry and proprietary surface deactivation technology to achieve lower bleed levels while maintaining selectivity virtually identical to their conventional counterparts. The document highlights benefits such as extended upper temperature limits (up to 360°C), improved inertness for acidic and basic samples, and shorter analysis times.

What's inside

  • Letter from Walt Jennings
  • Benefits of ms Grade Columns
  • Retention Indices at 90 C
  • Low Bleed Arylene Phases
  • DB-5ms Specifications
  • DB-XLB Specifications
  • DB-35ms Specifications
  • DB-17ms Specifications
  • DB-225ms Specifications

Specifications

Upper temperature limit (isothermal)325 C for DB-5ms, 340/360 C for DB-XLB and DB-35ms
Upper temperature limit (program)350 C for DB-5ms, 360 C for DB-XLB and DB-35ms
Selectivity typeStandard 5% phenyl siloxane phase
Selectivity type35% phenyl siloxane

Frequently asked questions

What makes J&W low bleed columns unique?

They utilize special surface deactivation and siloxane chemistries that enhance chromatographic performance while adhering to tight quality control specifications.

Do ms columns shift analyte retention?

No, in most cases all benefits of low bleed columns can be realized without any noticeable shift in analyte retention.

What is the benefit of DB-XLB?

DB-XLB has no conventional counterpart and offers excellent inertness, higher temperature limits, and unique selectivity for trace analytical work.