Start here

Siemens MM440 Drive ES for PCS7 V6.1 Quick Start Guide
This guide provides a brief introduction to the Siemens MM440 Drive ES that integrates with the PCS7 V6.1 automation system. It lists the required software environment (Windows 2000, XP, Server 2003) and the minimum PCS7 version (V6.1 or higher, STEP 7 ≥ V5.3.1.1, WinCC ≥ V6.0.3.0). The document also defines key terms such as PCS7, Drive ES, Integrated DP, and Ylink.
The manual includes configuration details for PROFIBUS DP slave properties, control and status word structures, and parameter tables for setpoints, actual values, and fault messages. Reference tables for SIMATIC master drives, SIMO modules, and SINAMICS serials are provided to aid system engineers during setup and troubleshooting.
Siemens MM440 specifications
| Power range | 0.12‑3 kW (low power) to 0.37‑200 kW (high power) |
|---|---|
| Output frequency | 0‑650 Hz (V/F control) / 0‑200 Hz (vector control) |
| Efficiency | 96%‑97% |
| Protection class | IP20 |
All Siemens MM440 documents by type
Disassembly, diagnostics and part numbers, for repair.
The shortest path to a working setup, usually only a few pages.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
How do I reset a fault on the MM440?
When a fault occurs, the panel shows the fault code; after clearing the cause, press the key to confirm fault reset and the drive returns to ready state.
What are the steps for quick debugging of the MM440?
Enter the quick‑debug mode, set the motor parameters (voltage, current, power), select the power unit and frequency, then start the drive to verify operation.
Which operating systems are supported for the MM440 Drive ES?
The guide lists Windows 2000, Windows XP, and Windows Server 2003 as supported operating systems.
From: Siemens MM440 Drive ES for PCS7 V6.1 Quick Start Guide
What PCS7 version is required to use the MM440 Drive ES?
PCS7 V6.1 or higher is required, with STEP 7 version ≥ V5.3.1.1 and WinCC version ≥ V6.0.3.0.
From: Siemens MM440 Drive ES for PCS7 V6.1 Quick Start Guide
What energy‑saving percentage can be achieved for air‑compressor systems using Siemens frequency converters?
The case study shows a reduction of about 20 % in annual electricity consumption after installing the frequency converters.
From: Siemens MM440, ECO, 6SE92, MDV, MICROMASTER440 General Frequency Transformer Application Note