RIGOL DS70000 Manuals

ManualLib has 3 documents for the RIGOL DS70000: 2 user manuals, 1 application note. Every file can be read online or downloaded as a PDF for free.

User Manual 2Application Note 1

Key facts

Brand
Rigol
Model
DS70000
Documents
3
Languages
EN · ZH
Last added
2026-11-03

Start here

RIGOL DS70000 Oscilloscope User Manual

RIGOL DS70000 Oscilloscope User Manual

User Manual 342 pages · 21.7 MB · EN

This document is the user manual for the RIGOL DS70000 oscilloscope. It provides detailed instructions on setup, measurement, triggering, protocol decoding, and troubleshooting. Sections cover safety requirements, product features, quick start, vertical and horizontal system settings, trigger options, math operations, measurement parameters, digital voltmeter and frequency counter, eye analysis, jitter analysis, reference waveforms, pass/fail tests, RTSA, protocol decoding, serial bus compliance, multi-pane windowing, waveform recording, display control, storage, system utility functions, remote control, and troubleshooting. The manual also includes figures for appearance, interface, and gestures.

Read online

RIGOL DS70000 specifications

Sampling Rate20GSa/s
Storage Depth2Gpts
Supported ProtocolsCAN, CAN-FD, FlexRay, I2S, MIL-STD-1553, SPI, I2C, RS232/UART
Waveform Refresh Rate1 million waveforms per second

Source: RIGOL DS70000 CAN-FD Bus Analysis Application Guide

All RIGOL DS70000 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What standards does this oscilloscope conform to?

The product conforms to national and industrial standards in China, the ISO9001:2015 standard, and the ISO14001:2015 standard.

From: RIGOL DS70000 Oscilloscope User Guide

What should you do if the touch screen problem persists after checking?

You should contact RIGOL for assistance.

From: RIGOL DS70000 Oscilloscope User Guide

What is the DS70000 used for?

It is used for CAN-FD bus analysis and decoding.

From: RIGOL DS70000 CAN-FD Bus Analysis Application Guide

What is the maximum storage depth of the DS70000?

It has a maximum storage depth of 2Gpts.

From: RIGOL DS70000 CAN-FD Bus Analysis Application Guide

What is the warranty standard for this product?

The product conforms to the ISO9001:2015 standard and the ISO14001:2015 standard.

From: RIGOL DS70000 Oscilloscope User Manual

How can I contact RIGOL for support?

You can contact RIGOL via the E-mail [email protected] or the Website http://www.rigol.com.

From: RIGOL DS70000 Oscilloscope User Manual