RIGOL RP1005C Manuals

ManualLib has 3 documents for the RIGOL RP1005C (Other Electronics): 3 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 3

Key facts

Brand
Rigol
Model
RP1005C
Industry
Electronics
Documents
3
Languages
ZH
Last added
2026-10-16

Start here

RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

User Manual 67 pages · 873 KB · ZH

The document serves as a comprehensive guide for the RIGOL RP1003C, RP1004C, and RP1005C Current Probes. It details general safety precautions, including grounding requirements and environmental conditions to prevent damage or injury during operation.

The manual provides step-by-step instructions for measurement preparation, demagnetization, zero adjustment, and the actual measurement process. It also includes specific technical specifications for each model variant regarding bandwidth, input current range, gain, and physical dimensions. This manual is written in Chinese.

Read online

RIGOL RP1005C specifications

Bandwidth (RP1003C)DC to 50MHz (-3dB)
Bandwidth (RP1004C)DC to 100MHz (-3dB)
Rise Time (RP1003C)≤7ns
Maximum Continuous Input Range30Arms
Maximum Peak Current Value50A peak (non-continuous)
Gain0.1V/A
Amplitude Accuracy±1.0%rdg±1mV (≤30Arms)
Operating Temperature0°C to 40°C

Source: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

All RIGOL RP1005C documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum continuous input range for the RP1003C and RP1004C?

The maximum continuous input range is 30Arms, with reference to Appendix 2 for the relationship between max input current and frequency.

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

What is the maximum continuous input current for the RP1003C and RP1004C models?

The maximum continuous input range is 30Arms.

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

What is the measurement category for the RP1005C?

The RP1005C supports Measurement Category II and III.

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

What is the maximum peak current rating for the RP1003C?

The RP1003C has a maximum peak current of 50A, which is rated for non-continuous use.

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

What is the maximum rated voltage for the RP1003C and RP1004C?

The maximum rated voltage is 300V for CATI (insulated conductor).

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual

What is the maximum rated voltage for the RP1005C?

The maximum rated voltage corresponds to CAT II and III levels with an anticipated transient voltage of 4000V.

From: RIGOL RP1003C/RP1004C/RP1005C Current Probe User Manual