Key facts
Start here

Dell AMP01 Storage System Getting Started Guide
This guide describes the Dell AMP01 storage system and the steps for initial setup, including unpacking, rack installation, power cabling, turning on the system, and installing the bezel.
The system supports up to 15 hot-plug SAS and/or SATA II physical disks, two active/active RAID controller modules, redundant hot-plug power and cooling, and expansion to a second enclosure.
Dell P01S specifications
| Physical disks | Up to 15 1-inch-by-3.5-inch SAS and/or SATA II hot-plug physical disks (3.0 Gbps) |
|---|---|
| RAID controllers | 2 hot-pluggable active/active controllers |
| Cache per controller | 256 MB |
| Temperature sensors per controller | 1 |
| SAS connectors per RAID controller | 1 SAS Port 0 In, 1 SAS Port 1 In (if installed), and 1 SAS Port Out |
| Debug connector per RAID controller | 1 6-pin mini-DIN connector (debug port for Dell factory use only) |
| Ethernet connector per RAID controller | 1 10/100 BASE-T connection for out-of-band management of the enclosure |
| Backplane board connectors | 15 SAS physical-disk connectors; 2 power supply/cooling fan module connectors; 2 sets of RAID controller connectors (6 each); 1 control panel connector |
| Sensors | 2 temperature sensors |
| Front panel LEDs | 1 two-color system status LED and 2 single-color LEDs (one power, one nonfunctional) |
| Physical disk carrier LEDs | 1 single-color activity LED and 1 two-color status LED per disk |
| Power supply wattage | 488 W maximum continuous; 550 W peak |
| Heat dissipation | 200 W |
| Voltage | 100-240 V rated (actual 90-264 V) |
| Frequency | 47-63 Hz |
| Amperage | 7.2 A at 100 V; 3.6 A at 200 V |
| Available physical disk power per slot | Up to 1.3 A at +12 V and up to 1.5 A at +5 V |
| Height | 13.11 cm (5.16 inches) |
| Width | 44.63 cm (17.57 inches) |
| Depth | 48.01 cm (18.9 inches) |
| Weight (maximum configuration) | 35.37 kg (78 lb) |
All Dell P01S documents by type
Disassembly, diagnostics and part numbers, for repair.
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do I locate the Service Tag and Express Service Code?
The service tag and express service code are etched on the back of the computer below the USB ports, or listed in the security menu of the system setup program.
What are the requirements for returning items for warranty repair?
You must call Dell to obtain a Return Material Authorization Number, include a copy of the Diagnostics Checklist, and pack the equipment in original or equivalent packing materials.
How many physical disks can the Dell AMP01 support?
Up to 15 1-inch SAS and/or SATA II hot-plug physical disks.
How many RAID controllers does the system have?
Two hot-pluggable active/active RAID controllers.
How do you turn on the Dell AMP01 system?
With the host server off, complete all cabling for the system. Power on the system by turning on both power supply/cooling fan modules, then power on the host server.
What power source should be used?
Connect the power cables to a grounded electrical outlet or a separate power source such as a UPS or PDU.