Promega Nano-Glo Live Cell Assay System Quick Protocol (N2011, N2012, N2013)

Bilingual quick protocol for preparing Nano-Glo Live Cell Reagent and measuring luminescence from NanoLuc luciferase or NanoBiT assays in living cells…


Promega Nano-Glo Live Cell Assay System Quick Protocol (N2011, N2012, N2013) - cover page
Brand
Promega
Category
Chemical products
Document type
Quick Start Guide
Language
Chinese
Pages
2
File format
PDF
File size
483 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
25A090FFED0D7C19DBA27654CFE47D59

About this manual

This two-page quick protocol from Promega gives condensed instructions for the Nano-Glo Live Cell Assay System, Products N2011, N2012 and N2013. It is an excerpt of the full English protocol available at www.promega.com/protocols. The Nano-Glo Live Cell Reagent is a nonlytic detection reagent used to monitor luminescence from NanoLuc luciferase or NanoBiT assays in living cells; it contains the cell-permeable substrate furimazine plus a proprietary agent that reduces autoluminescence and assay background.

The document covers preparation of the reagent by combining 1 volume of Nano-Glo Live Cell Substrate with 19 volumes of Nano-Glo LCS Dilution Buffer, storage conditions for the components, and measuring luminescence in 96-well plates, including medium exchange, reagent addition, mixing and integration times. It notes that for NanoBiT assays, detailed protocols are in the NanoBiT Protein:Protein Interaction System Technical Manual #TM461. This manual is written in Chinese.

What's inside

  • Nano-Glo Live Cell Reagent 的制备 (Preparation of the Nano-Glo Live Cell Reagent)
  • 在96孔板中检测发光 (Measuring Luminescence in 96-Well Plates)
  • 试剂储存注意事项 (Reagent storage notes)
  • 信号稳定性 (Signal stability, Figure 2)
  • NanoBiT 检测参考技术手册 #TM461

Specifications

Reagent dilution1 volume substrate + 19 volumes dilution buffer (20-fold)
Substrate storage temperature-20°C
Reconstituted reagent activity loss at 20°C10% in approximately 3 hours
Reconstituted reagent activity loss at 4°C10% in approximately 7 hours
Medium volume per 96-well100µl buffered cell culture medium with 0–10% (v/v) FBS
Reagent volume per well25µl
Mixing15 seconds at 300–500 rpm (orbital shaker) or by hand
Integration time0.25–2 seconds
Continuous measurement durationup to 2 hours

Frequently asked questions

How should the Nano-Glo Live Cell Substrate be stored?

Store the Nano-Glo Live Cell Substrate at –20°C. Thaw the Nano-Glo LCS Dilution Buffer upon first use and store it at room temperature.

How do I prepare Nano-Glo Live Cell Reagent?

Combine 1 volume of Nano-Glo Live Cell Substrate with 19 volumes of Nano-Glo LCS Dilution Buffer (a 20-fold dilution); for example, add 1ml of substrate to 19ml of dilution buffer for 20ml of reagent.

Can the reconstituted Nano-Glo Live Cell Reagent be stored?

No, it should be made fresh for each experiment; Promega does not recommend long-term storage of the solution at any temperature.

Do the cells remain intact during the luminescence measurement?

Yes, the reagent is nonlytic and cells remain intact after adding Nano-Glo Live Cell Reagent.