This technical note defines methods and criteria for measuring and estimating junction temperatures for Micron memory components to ensure reliability and…
This technical note provides a general method and criteria for measuring and ensuring that Micron memory components and modules do not exceed the maximum allowable temperature. It defines specific temperature terms, thermal resistance parameters, and methods for estimating junction temperature based on case and board temperatures. The document also discusses power consumption and thermal modeling to help ensure the reliability and functionality of Micron's memory components as defined in production data sheets.
The maximum junction temperature for Commercial DRAM is 85°C.
The maximum junction temperature for Industrial DRAM is 95°C.
The memory should be exposed to 1m/s or more of moving air for optimal cooling conditions.
Case temperature should be measured by gluing a thermocouple to the top center of the component with a 1mm bead of conductive epoxy.