Xinling JD1A Electromagnetic Speed Control Motor Controller User Manual

The JD1A electromagnetic speed‑control motor controller manual covers operation, wiring, testing, adjustment, troubleshooting and maintenance.


Xinling JD1A Electromagnetic Speed Control Motor Controller User Manual - cover page
Brand
JD
Category
Motor
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
805 KB
Published
12 March, 2012
Updated
30 September, 2026
MD5 checksum
3757C0224F8B2EB76EBCD2FAC5145A3D

About this manual

The JD1A electromagnetic speed control motor controller is used for speed control of electromagnetic speed-regulating motors, providing constant-torque stepless speed regulation. The manual covers model meaning, operating conditions, specifications, panel layout, operating principle, wiring, pre-use testing, adjustment, use, dimensions, faults and maintenance.

It applies to JD1A-11, JD1A-40 and JD1A-90 units for motors from 0.55 kW to 90 kW, with AC 220 V input and DC 90 V output. Operating conditions include altitude up to 1000 m, ambient temperature from -5 to +40 C, relative humidity up to 90%, and an IP5X sealed plastic enclosure. This manual is written in Chinese.

What's inside

  • Model meaning
  • Operating conditions
  • Model specifications and technical data
  • Controller panel layout
  • Basic operating principle
  • Controller wiring
  • Pre-use testing
  • Controller adjustment
  • Outline and installation dimensions
  • Common faults and troubleshooting

Specifications

Power supplyAC 220 V ±10%, 50~60 Hz
Maximum output ratingDC 90 V, 3 A / 5 A / 8 A
Controllable motor power0.55~11 kW, 11~40 kW, 40~90 kW
TachogeneratorThree-phase medium-frequency voltage, ratio ≤2 V/100 r/min
Speed range100~1420 r/min
AltitudeNot more than 1000 m
Ambient temperature-5 to +40 C
Relative humidityNot more than 90% (below 20 C)
Vibration10~150 Hz, maximum acceleration 0.5 g
Grid voltage fluctuation≤10% of rated value
Dust protectionIP5X

Frequently asked questions

What should I check if the motor runs only at high speed and cannot be adjusted?

Check the motor for phase rubbing, check the feedback potentiometer, and change the sync signal voltage polarity.

What causes periodic speed oscillation?

Reversed excitation leads or damaged C4/C7 capacitors; swap the 3 and 4 polarity or replace C4/C7.

How is the controller tested before use?

Wire it as shown in Figure 2, turn on power and the main switch, rotate the speed potentiometer, and check for a 0~90 V jump voltage at the output.

What is the dust protection rating of the enclosure?

The sealed plastic enclosure has an IP5X dust protection rating.


Error codes in this manual

This manual explains 5 error codes. Open a code for its meaning, causes and what to do:

1'2'3'4'5'

All error codes of this product →