Ultrasonic Sensors Series UFA-150, UFA-200 Installation Guide
This installation guide covers unpacking, mounting, and electrical connection of WayCon UFA-150 and UFA-200 ultrasonic sensors. It also explains teach-in procedures for analog and switching outputs, sound cone geometry, and operating notes.
The guide includes technical drawings, accessory cable information, and a declaration of EC conformity for the UFA-150 and UFA-200 sensor series.
| Mounting hardware | Two M12 nuts (HEX 17) included |
|---|---|
| Teach-in voltage duration | At least 1 s |
| Analog output lower limit | 0 V or 4 mA |
| Analog output upper limit | 10 V or 20 mA |
| Smooth surface inclination angle | Up to 10° |
| Minimum foil thickness | At least 0.01 mm |
| Beam diameter at 0 mm | ca. 3 mm (UFA-150-FB), ca. 9 mm (UFA-200) |
| Maximum beam diameter | ca. 15 mm (UFA-150-FB), ca. 23 mm (UFA-200) |
The voltage must be active for at least 1 s on the teach wire.
Smooth surfaces can be detected up to an inclination angle of 10°.
Measurements under pressure higher than atmospheric pressure are not possible with ultrasound sensors.
The foil thickness should be at least 0.01 mm.