VR12F-TF222-005EN Instruction Manual

VR12F-TF222-005EN Page 1 of 1 Instruction Manual AND Valve with One-touch Fittings Series VR1211F The intended use of this product is to control pneumatic signal lines.


VR12F-TF222-005EN Instruction Manual - cover page
Brand
SMC
Category
Other
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
165 KB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
C422FF6392CA5EA73AE096ED656E9CDA

About this manual

This one-page instruction manual from SMC covers the AND Valve with One-touch Fittings, Series VR1211F (document VR12F-TF222-005EN). The product's intended use is to control pneumatic signal lines, and the valve acts as an AND logic element in an all-air circuit: air flows to the OUT side only when air is supplied to both P1 and P2 inputs.

The manual provides safety instructions with Caution, Warning and Danger levels, valve specifications (proof pressure 1.5 MPa, max operating pressure 1.0 MPa, applicable tubing materials nylon, soft nylon and polyurethane), installation and environment requirements, piping and air supply guidance, maintenance procedures, limitations of use, and disposal instructions. It also notes that the valve cannot be used as an emergency shut-off valve or for holding pressure.

What's inside

  • Safety Instructions
  • Specifications
  • Installation
  • How to Order
  • Outline Dimensions
  • Maintenance
  • Limitations of Use
  • Product Disposal
  • Contacts

Specifications

FluidAir
Proof pressure1.5 MPa
Max. operating pressure1.0 MPa
Min. operating pressure0.05 MPa
Ambient and fluid temperature-5 to 60 °C (No freezing)
Applicable tubing materialNylon, Soft nylon, polyurethane
Min. operating frequency1 cycle / 30 days
Max. operating frequency2 Hz
LubricationNot required
Impact resistance1000 m/s2
Vibration resistance50 m/s2
Mounting orientationUnrestricted

Frequently asked questions

When does air flow to the OUT side of the VR1211F AND valve?

Air flows to the OUT side only when air is supplied to both P1 and P2. When the pressures differ, the lower pressure flows to the OUT side, and if air is supplied to only one input, it does not flow to the OUT side.

Can the VR1211F be used as an emergency shut-off valve?

No, the product is not designed for safety applications such as an emergency shut-off valve; other reliable safety assurance measures should be adopted in such systems.

Does the valve require lubrication?

No, SMC products are lubricated for life at manufacture and do not require lubrication in service. If a lubricant is used in the system, refer to the catalogue for details.

What air filter is recommended upstream of the valve?

Install an air filter upstream of the valve with a filtration size of 5 μm or smaller.