AMETEK Gemco Series 1746R PLC Resolver Interface Module for SLC 500 Installation & Programming Manual

This manual will instruct the user in installing and programming the Series 1746R Gemco PLC Resolver Interface Module.


AMETEK Gemco Series 1746R PLC Resolver Interface Module for SLC 500 Installation & Programming Manual - cover page
Brand
Ametek
Category
Automation control Equipment
Document type
Programming Manual
Language
English
Pages
28
File format
PDF
File size
420 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
ED6ED8D00044EE9BAC7787E6B57EB8D5

About this manual

The AMETEK Gemco Series 1746R PLC Resolver Interface Module is a resolver-based unit that uses Allen-Bradley SLC 500 I/O interface technology and is compatible with the A-B Series 1746R I/O chassis. It monitors machine or process position and delivers absolute position data with up to 12-bit (4096-count) resolution per turn to the SLC 500 processor.

The manual covers installation in an SLC 500 rack, resolver and cable installation, input wiring, setup and programming through the I/O image table, application examples, specifications and wiring diagrams. It describes the 1746R-1 single-axis version, the 1746R-2 dual-axis version, and the face-panel RUN and FAULT LEDs.

What's inside

  • Introduction & Overview
  • Face Panel Description
  • Installation
  • Resolver Installation
  • Resolver Cable Installation
  • Set-Up & Programming
  • I/O Image Table
  • Application Examples
  • Specifications
  • Wiring Diagram

Specifications

ResolutionUp to 12 bit (4096 count) per turn
I/O image table capacity8 input words and 8 output words
Configuration ID code3535
Maximum resolver cable length1,000 feet with Belden 9873 or equivalent
CompatibilityCompatible with A-B Series 1746R I/O chassis
Recommended resolverGemco Series 1986 Resolvers
Version 1746R-1Single-axis applications; single-turn resolver
Version 1746R-2Dual-axis applications; can use two single-turn resolvers

Frequently asked questions

What is the ID code for the 1746R module?

The ID code is 3535; it tells the processor that the module uses 8 input words and 8 output words.

What is the maximum resolver cable length?

The maximum cable length is 1,000 feet using Belden 9873 or equivalent cable.

What does the green RUN LED indicate?

It indicates that the card is operational.

What does the red FAULT LED indicate?

It indicates a card fault or a resolver (transducer) fault.

Download PDF (420 KB)

More Ametek Manuals