The VFD-C200 Series AC Motor Drive is manufactured with high-quality components and materials and incorporates the latest microprocessor technology available.
This manual covers installation, parameter setting, troubleshooting, and daily maintenance for Delta VFD-C200 Series AC motor drives. The provided pages include safety guidelines, receiving and inspection, nameplate and model-name information, dimensions, RFI jumper guidance, and grounding requirements.
The table of contents lists chapters on installation, wiring, main and control terminals, optional accessories, specifications, digital keypad, parameter settings, warning and fault codes, CANopen, PLC function, and standard-drive error corrections.
| Frequency range | 0-600 Hz (normal and heavy duty) |
|---|---|
| Frame A0 dimensions (first listed model group) | 110.0 x 180.0 x 160.0 mm (W x H x D) |
| Frame A0 dimensions (second listed model group) | 110.0 x 180.0 x 151.0 mm (W x H x D) |
| Model input voltage codes | 21: 230 V 1-phase; 23: 230 V 3-phase; 43: 460 V 3-phase |
| Frame A0 screw torque | 8-10 kg-cm (6.9-8.7 lb-in) |
| Storage temperature (no charge over 3 months) | Not higher than 30 °C |
Inspect it for shipping damage, confirm the package part number matches the nameplate, and verify the wiring voltage range.
The frequency range is 0-600 Hz for both normal duty and heavy duty.
It must be removed for floating ground (IT) or asymmetric ground (corner-grounded TN) systems.
The ambient temperature should not be higher than 30 °C.