This document provides the operation manual for VBAT-M35A air tank VBAT05A1-U-X104 VBAT10A1-U-X104.
This SMC operation manual covers the VBAT-M35A air tank, including models VBAT05A1-U-X104 and VBAT10A1-U-X104. It describes component specifications, operating cautions, connection to booster regulators, and regular maintenance checks.
The tank complies with the Chinese Pressure Vessel Code (TSG R0003-2007) and has a maximum operating pressure of 1.5 MPa. It is designed for use with SMC VBA1 and VBA2 booster regulators.
| Max. operating pressure | 1.5 MPa |
|---|---|
| Material | Q235B |
| Tank capacity | 5 L / 10 L |
| Temp. range | 0 to 75oC |
| Tank mass | 6.6kg / 11.5kg |
| Applicable booster regulator | VBA1 / VBA2 |
The maximum operating pressure is 1.5 MPa.
The air tank is applicable to booster regulators VBA1 and VBA2.
It complies with TSG R0003-2007, the Supervision Regulation on Safety Technology for Simple Pressure Vessels.
The VBAT05A1-U-X104 has a 5 L capacity and the VBAT10A1-U-X104 has a 10 L capacity.