F Series Servo Press Installation and Maintenance Manual, introduces the machine's safety precautions before, during and after use, and provides detailed instructions on the machine's component description, configuration description, wiring description and other contents.
This document is the Installation and Maintenance Manual for the Delta AM-ASP-F Series servo press. It provides safety guidelines, system structure descriptions, and detailed wiring instructions for various power and communication configurations.
The guide details installation procedures for different machine models, including hoisting and fixing methods. It also covers maintenance tasks such as belt replacement, lubrication, and pressure calibration, along with a troubleshooting section for common alarms and error codes. This manual is written in Chinese.
| Operating Temperature | 0°C ~ 55°C |
|---|---|
| Operating Humidity | 0 ~ 90% RH (no condensation) |
| Altitude Limit | 2,000M or below |
| Protection Rating | IP20 |
| Power Supply (Small Models) | AC 220V 1 Phase 50/60Hz 10A |
| Power Supply (Large Models) | AC 220V/380V 3 Phase 4 Wire 50/60Hz 30A |
When moving the press, wear protective shoes such as steel-toed shoes to avoid injury if the machine falls.
To release the brake, press the emergency stop button, support the spindle, remove the cover, and connect an external 24V DC power supply to the brake module.
The belt tension for F001/F002 models should be 54±10% N.