GRX Reflective sign retroreflector measurement instrument is a portable device for detecting the retroreflection coefficient of road traffic signs, reflective clothing, retroreflective tape and vehicle license plates. It measures RA value (night retroreflection coefficient) and has the models GRX-1, GRX-3 and GRX-7.
The GRX user manual describes a portable field quality-control device for measuring the retroreflection coefficient (RA) of road traffic signs, reflective clothing, retroreflective tape and vehicle license plates. It covers the GRX-1, GRX-3 and GRX-7 models, which provide 1, 3 or 7 observation angles, and states that the device uses LED light source technology and a color touchscreen.
The manual explains the angle lens, measurement models for ASTM and CEN configurations, battery and safety information, calibration, specifications and delivery accessories. Measurement data can be stored internally and transferred by USB; optional features include Wi-Fi, GPS and a camera. This manual is written in Chinese.
| ASTM standards | ASTM E 1709; ASTM E1809 |
|---|---|
| CEN standard | CEN EN 12899 |
| Safety standard | CEN EN 20471 |
| Incident angle | -4° |
| Observation angles | 0.2°, 0.33°, 0.5°, 0.7°, 1.0°, 1.5°, 2° |
| Measurement range | φ25 mm / 0.1 inch |
| Battery | Rechargeable 10.8 V / 2 Ah lithium battery |
| Charging time | Approximately 45 minutes |
| Data storage | 2,000,000 measurements without images; 2,000 with images |
| Operating temperature | 0°C to 60°C (32°F to 140°F) |
| Weight | 1.9 kg / 4.2 lbs |
It measures the RA value, the nighttime retroreflection coefficient, for materials such as road signs, reflective clothing, tape and license plates.
The GRX models offer up to 7 observation angles: 0.2°, 0.33°, 0.5°, 0.7°, 1.0°, 1.5° and 2.0°.
The manual lists EN 12899, EN 20471, ASTM E 1709, ASTM E2540 and ASTM E1809 for the GRX.
The manual recommends calibration verification every day using the supplied calibration module, and at least once a day during use.