Introduces the function characteristics of the digital flow switch PF2M7## series products and the use precautions
This instruction manual covers the SMC PF2M7 series integrated digital flow switch, which monitors and displays flow information. It provides safety instructions, specifications, names of individual parts, and details about the display and controls.
The product is class A equipment intended for industrial environments. Follow the caution, warning, and danger notices and comply with relevant safety laws and standards before installation or operation.
| Applicable fluid | Dry air, N2, Ar, CO2 |
|---|---|
| Fluid temperature range | 0 to 50 oC |
| Operating pressure range | -0.1 to 0.75 MPa |
| Power supply voltage | 12 to 24 VDC ±10% |
| Current consumption | 35 mA or less |
| Display type | LCD |
Dry air, nitrogen, argon, and carbon dioxide meeting ISO 8573-1 classes 1.1.2 to 1.6.2 are applicable.
The operating pressure range is -0.1 to 0.75 MPa.
Yes, it is class A equipment intended for use in an industrial environment.