WAY-CON WAY-AX Digital Display Module User Manual

The WAY-AX series of manual digital displays has two universal 16-bit analog inputs that can be used for -10 … +10 V / 0 … 10 V / 0 … 20 mA / 4 … 20 mA inputs, as well as a high-accuracy reference output of 10 V for potentiometers> 1 kOhm. The high-contrast display has event-dependent color variations and emulates a 7-segment display, including icons and units. The WayCon Positionsmesstechnik GmbH device is intuitive and easy to parameterize using plain text and a touchscreen. It also has a 24 V auxiliary output for encoder power, totalization for each input, linearization with 24 control points for each input, and many other features such as tara, an averaging filter, and a sampling time for each input. The device is encased in a 96 x 48 mm standard panel with IP65 protection.


WAY-CON WAY-AX Digital Display Module User Manual - cover page
Brand
Waycon
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
60
File format
PDF
File size
2.2 MB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
2625193910A97A221D8DEEEF35D0C3D2

About this manual

The WAY-CON WAY-AX is a digital display module designed for industrial machines and systems. It features two universal 16-bit analog inputs supporting voltage and current signals, a high-contrast display with emulation of 7-segment displays, and intuitive touchscreen parameterization. The device supports various operation modes, including single-channel and dual-channel configurations with sum, difference, multiplication, and division functions.

What's inside

  • Safety Instructions
  • Installation
  • Electrical Connections
  • Analog Input
  • Reference Output
  • Operation Mode
  • Parameter Menu
  • Serial Interface
  • Error Messages
  • Technical Specifications

Specifications

Analog InputsTwo universal 16 bit analog inputs
Reference Output10 V
Display Size96 x 48 mm
Protection ClassIP65
Power Supply (DC)18 to 30 V
Auxiliary Output Voltage (DC)Approx. 1 V lower than supply

Frequently asked questions

What are the available operation modes?

The device supports SINGLE, DUAL, IN 1 + IN 2 (sum), IN1 – IN 2 (difference), IN 1 x IN 2 (multiplication), and IN 1 / IN 2 (division) modes.

What is the maximum current for the reference output?

The reference output should be loaded with a maximum of 10 mA.

How should the device be cleaned?

Use only a slightly damp (not wet), soft cloth for the front; no cleaning is necessary for the rear during normal operation.