Agilent 1200 Infinity Series Variable Wavelength Detectors Technical Overview

This document introduces the performance characteristics of the Agilent 1200 Infinity Series Variable Wavelength Detectors, including faster results, improved sensitivity and absolute data security. The series detectors have two versions: Agilent 1260 Infinity VWD (G1314F) and Agilent 1290 Infinity VWD (G1314E), the latter with high sampling rates for ultra-fast HPLC and UHPLC. These detectors offer the following features and benefits: Higher sampling rates up to 160 Hz for ultra-fast HPLC (Agilent 1290 Infinity VWD) or up to 80 Hz (Agilent 1260 Infinity VWD); Data Recovery Card (DRC) provides for unique 'data-never-lost insurance' (Agilent 1290 Infinity VWD); Deuterium lamp for highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm; Optional flow-cell cartridges such as standard (10 mm path length/14 µL volume), high pressure (10 mm/14 µL), micro (3 mm/2 µL) and semi-micro (6 mm/5 µL) are available and can be deployed according to application needs; Easy front access to flow cell and lamp for fast replacement; Flow cell and lamp with RFID tag for safe identification; Lamp information, including part number, serial number, production date, number of ignitions, total burn time; Cell information, including part number, serial number, production date, nominal path length, volume, maximum pressure; Built-in electr.


Agilent 1200 Infinity Series Variable Wavelength Detectors Technical Overview - cover page
Brand
Agilent
Category
Other Electronics
Document type
Product Leaflet
Language
English
Pages
8
File format
PDF
File size
794 KB
Published
05 July, 2012
Updated
30 September, 2023
MD5 checksum
8E574D3BB04A6D78C860F8F664D8C0A2

About this manual

This document provides a technical overview of the Agilent 1200 Infinity Series Variable Wavelength Detectors (VWD), specifically the Agilent 1260 Infinity VWD (G1314F) and the Agilent 1290 Infinity VWD (G1314E). These detectors are designed for highest optical performance, compliance with GLP regulations, and easy maintenance, offering higher sampling rates up to 160 Hz for ultra-fast HPLC and UHPLC applications.

What's inside

  • Introduction
  • Optical design
  • Data sampling rates
  • Noise and drift
  • Limit of detection
  • Detection of impurities
  • Performance comparison

Specifications

Sampling rate (1290)up to 160 Hz
Sampling rate (1260)up to 80 Hz
Wavelength range190 to 600 nm
Entrance slit1 mm standard
Band widthtypically 6.5 nm
Noise improvementfactor of 3.4
Drift improvement2.4-fold
Signal-to-noise ratio improvementfactor of 4.6

Frequently asked questions

Which models are available in the Agilent 1200 Infinity Series VWD?

Two versions are available: the Agilent 1260 Infinity VWD (G1314F), and the Agilent 1290 Infinity VWD (G1314E) with high sampling rates.

What is the wavelength range for the deuterium lamp?

The deuterium lamp covers a wavelength range of 190 to 600 nm.

How much does the baseline noise improve compared to the earlier model?

The experimental data shows an improvement in baseline noise by a factor of 3.4.