Agilent Bond Elut SCX and SampliQ Si-SCX Technical Overview

A comparison study was conducted to evaluate the recovery of two basic amines using two silica-based strong cation exchange (SCX) solid phase extraction (SPE) products. Acidic and neutral impurities were spiked into human plasma to assess the selectivity for amines only. Both Agilent Bond Elut SCX and SampliQ Si-SCX showed comparable and consistent recoveries for the basic compounds used in this study. The use of Bond Elut SCX resulted in a clean extract and high recovery of basic compounds, such as amines.


Agilent Bond Elut SCX and SampliQ Si-SCX Technical Overview - cover page
Brand
Agilent
Document type
Product Leaflet
Language
English
Pages
8
File format
PDF
File size
890 KB
Published
05 July, 2012
Updated
28 September, 2023
MD5 checksum
08690818BB5B31A1C104225FFEAB0E61

About this manual

This document presents a technical overview comparing the performance of two silica-based strong cation exchange (SCX) solid phase extraction products: Agilent Bond Elut SCX and Agilent SampliQ Si-SCX. The study evaluates their ability to recover basic amines, specifically procainamide and chlorpromazine, from human plasma while retaining acidic and neutral impurities.

The results indicate that both cartridges provide comparable recovery rates for the target basic compounds (90-98%). However, the Bond Elut SCX cartridge demonstrated superior performance by offering a cleaner extract with fewer interferences compared to the SampliQ Si-SCX under the tested conditions. The document also details the specific sample preparation scheme and HPLC chromatographic conditions used for analysis.

What's inside

  • Introduction
  • Study Purpose and Methodology
  • Sample Processing Scheme
  • SPE Cartridge Properties
  • Recovery Results
  • Chromatograms
  • Calibration Linearity
  • HPLC Conditions
  • Conclusion

Specifications

Bond Elut SCX Part Number12102013
SampliQ Si-SCX Part Number5982-2111

Frequently asked questions

Which Agilent SCX cartridge provides a cleaner extract?

The Bond Elut SCX offers a cleaner extract relative to the SampliQ Si-SCX under the tested conditions.

What is the recovery range for basic amines using these cartridges?

Similar recoveries are observed for both cartridges, ranging from 90% to 98%.

What HPLC column is recommended for analyzing the extracts?

The study used an Agilent ZORBAX Rapid Resolution Eclipse Plus C18 column.