Agilent Air Monitoring Solutions Application Compendium

This collection of Application Briefs demonstrates the wide range of analyses that can be successfully addressed with the Agilent TD-GC/MS systems, including monitoring air toxics, monitoring hazardous air pollutants, soil gas and vapor-intrusion assessments, sorbent tube stack emissions testing, occupational hygiene/workplace air monitoring, fugitive emissions, odor, and fence-line monitoring, and indoor air quality.


Agilent Air Monitoring Solutions Application Compendium - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
20
File format
PDF
File size
1010 KB
Published
02 July, 2012
Updated
01 October, 2023
MD5 checksum
AA67FBDA6E7A9E26563CE61890DB5F7A

About this manual

Thermal desorption (TD) combined with Gas Chromatography/Mass Spectrometry (GC/MS) is a powerful technique for measuring organic vapors in air. Agilent Technologies partners with Markes International to provide state-of-the-art air analyzers that comply with various international standard methods, including U.S. EPA Methods TO-15 and TO-17.

The document outlines diverse applications such as monitoring air toxics using canisters and sorbent tubes, soil gas assessments, stack emissions testing, occupational hygiene, and indoor air quality analysis. The systems feature cryogen-free operation, versatile water management, and high-performance components like the Agilent 7890A GC system and 5975C Series GC/MSD.

What's inside

  • Monitoring Air Toxics
  • Soil Gas and Vapor Intrusion
  • Stack Emissions Testing
  • Occupational Hygiene
  • Fugitive Emissions Monitoring
  • Indoor Air Quality
  • System Configuration Requirements
  • Sampling and Analytical Conditions

Specifications

Compatible MethodsISO/EN 16017, ASTM D6196, U.S. EPA Methods TO-17 and TO-15, EN 14662 (parts 1 and 4), NIOSH 2549
GC System ModelAgilent 7890A
MS System ModelAgilent 5975C Series GC/MSD
Sample Volume Range100 mL to 1L
Focusing Trap Temperature Program25 °C, 40 °C/s to 320 °C (3 min)
TD Flow Path Temperature140 °C
Carrier Gas PressureHelium at constant pressure of 10 psi
MS Full Scan Range35-300 m/z

Frequently asked questions

Which U.S. EPA methods are supported for air toxics monitoring?

The systems support U.S. EPA Method TO-17 for sorbent tubes and U.S. EPA Method TO-15 for canisters.

Does the system require liquid cryogen?

No, the systems utilize electrically-cooled focusing technology that requires no liquid cryogen.

What is the recommended column for air toxics analysis?

The recommended accessory includes an Agilent J&W DB-624 column with specifications of 60 m x 0.32 mm id x 1.8 pm.