Lapp Limited's Olflex® Classic 400P is a polyurethane control cable with excellent oil, UV and microbial resistance. It is suitable for control and power cable applications in machine tools and mechanical engineering.
The Olflex® Classic 400P cable is an oil‑resistant control cable with a polyurethane outer sheath, suitable for flexible use and fixed installation in dry, damp and wet rooms. It is microbe‑proof, hydrolysis resistant, and can withstand medium mechanical abuse, making it ideal for machine tools and mechanical engineering applications.
Technical data include a bare copper conductor (IEC 60228), LAPP special PVC core insulation, a polyurethane outer sheath (VDE 0282‑10), nominal voltage 300/500 V, test voltage 4000 V AC, temperature ranges of –5 °C to +70 °C (flexible) and –40 °C to +80 °C (fixed), minimum bending radii of 12.5 × cable diameter (flexible) and 4 × cable diameter (fixed), oil resistance per VDE 0472 part 803, and compliance with EC directive 73/23/EEC.
| Conductor | bare copper, fine wire strand (IEC 60228) |
|---|---|
| Core insulation | LAPP special PVC compound P8/1 |
| Outer sheath | Polyurethane compound TMPU (VDE 0282‑10) |
| Nominal voltage | 300/500 V |
| Test voltage | 4000 V AC |
| Temperature range (flexible use) | -5 °C to +70 °C |
| Temperature range (fixed installation) | -40 °C to +80 °C |
| Minimum bending radius (flexible use) | 12.5 × cable diameter |
| Minimum bending radius (fixed installation) | 4 × cable diameter |
| Oil resistance | VDE 0472 part 803 test method B |
| EC directive compliance | ECD 73/23/EEC (Low Voltage Directive) |
It can be used in dry, damp and wet rooms for both flexible use and fixed installation.
The cable is rated for a nominal voltage of 300/500 V.
Yes, it is an oil‑resistant control cable with a polyurethane outer sheath.