The Delta CME-PD01 is a communication module that links VFD-E series AC drives to a PROFIBUS-DP network. It features a DB9 PROFIBUS-DP interface, an RJ-45 RS-485 port for drive connection, two status LEDs, and rotary address switches for node configuration.
The manual covers receiving and inspection, product overview with layout and technical information, PROFIBUS and PROFIBUS-DP introduction, installation and pin assignment, communication settings including address, parameters, cyclical data, and PKW access, GSD file parameter configuration, troubleshooting with LED diagnostics and error codes, and mechanical dimensions.
| Supported baud rates | 9.6 kbaud to 12 Mbaud |
|---|---|
| Status LEDs | SP LED (drive link), NET LED (PROFIBUS link) |
| Address setting | Two rotary switches ADDH (high 4 bits) and ADDL (low 4 bits) |
| Drive interface | RS-485 (RJ-45), 8-pin cable, 15 V DC supplied by VFD-E |
| Data exchange | Cyclical PZD and PKW parameter access, SYNC/FREEZE support |
| Dimensions | 57.3 × 59.7 × 3.6 mm (approx.) |
The module supports baud rates from 9.6 kbaud up to 12 Mbaud.
The address is set with two rotary switches: ADDH for the high 4 bits and ADDL for the low 4 bits.
SP LED shows the connection status between the module and the VFD-E drive; NET LED shows the connection status between the module and the PROFIBUS-DP network.
It receives 15 V DC from the VFD-E drive through the 8-pin RJ-45 communication cable.