Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Serial format error occurs when the data format from an OHA-type detector or serial absolute position linear scale is invalid. The manual lists no action for this code.
Communication error happens when a detection system using an OHA-type detector and serial linear scale reports a communication fault. The manual lists no action for this code.
Low-speed communication err occurs when initial communication with the absolute position linear scale cannot be established. The manual's first action is: “PR”
Tool double registration means a tool number is registered twice, indicating duplicate entry in the system. The manual's first action is: “Change the tool No.”
Network error indicates any communication issue beyond SYW0070 to SYW0073 has occurred during data transmission. The manual's first action is: “Check the cause.”
No dial tone occurs when the phone line is not connected to an analog modem during a dialing attempt. The manual's first action is: “Connect the phone line.”
Redial over happens when dialing attempts fail and exceed the allowed number of redials. The manual's first action is: “Check the number of redials setting.”
Modem initial error occurs when the modem fails to establish communication after being powered on due to detected errors. The manual's first action is: “Connect the model and turn the power ON again.”
Receive result of diagnosis means the system has successfully received and logged diagnostic data from a file. The manual's first action is: “Erase the message.”
PLC-H timer over happens when the PLC’s high-speed process exceeds its allocated time limit. The manual's first action is: “Shorten the high-speed process.”
Low battery voltage means the battery supplying data-saving power in the NG has dropped below acceptable levels. The manual's first action is: “Charge the battery.”
The others EMG indicates an emergency stop occurred for some other reason, not directly related to the system's primary controls. The manual's first action is: “Contact the Service Center.”
RIO4 communication error occurs when the emergency stop signal from the remote IO unit (R104) is detected due to a disconnected communication cable. The manual's first action is: “Check and remove the cause of the rem…
An emergency stop occurred because the servo terminator or battery is not connected properly. The manual's first action is: “Check the connection status of the servo communication cable and connectors.”
This appears when the power is OFF. The manual's first action is: “This is not a particular problem.”