An internal interlock occurred due to an excessively large pre-interpolation acceleration/deceleration time constant. The manual's first action is: “Reduce the command speed, or reduce the parameter setting value for …
Starting is not possible because an axis is already being controlled. The manual's first action is: “Restart after stopping the axis being controlled.”
The synchronous correction mode switch was turned ON in a non-handle mode. The manual's first action is: “Select the handle mode.”
Starting was attempted during machining time calculation mode. The manual's first action is: “Wait for the machining time calculation to complete, or restart after canceling the machining time calculation by resetting.”
Starting was attempted during the reset process. The manual's first action is: “Restart after the reset process is completed.”
Starting was attempted during buffer correction. The manual's first action is: “Cancel the buffer correction by resetting or screen changeover. Complete the buffer correction by pressing the (INPUT CALC) key.”
Starting was attempted during a program check or program check mode. The manual's first action is: “Wait for the program check to complete, or restart after canceling the program check by resetting.”
Operation was attempted during a program search process. The manual's first action is: “Wait for the program search to complete, or restart after canceling the program search by resetting.”
Starting was attempted without setting an MDI in MDI mode. The manual's first action is: “Restart after setting an MDI.”
Automatic start is not possible because the axis has not returned to the program restart position. The manual's first action is: “Manually return the axis to the restart position, or turn ON the Auto restart valid par…
Restarting was attempted before the program restart search was completed. The manual's first action is: “Restart after the program restart search is completed.”
The restart switch was turned ON before restart search completion and manual mode was selected. The manual's first action is: “Search the block to be restarted. Turn OFF the restart switch.”
An interlock signal has been input that locks the start of a cutting block in the sequence program. The manual's first action is: “Check the sequence program. Restart the program while simultaneously canceling the sig…
An interlock signal has been input that locks the start of a block in the sequence program. The manual's first action is: “Check the sequence program. Restart the program while simultaneously canceling the signal.”
The spindle stopped during synchronous feed command, possibly due to broken encoder cable or non-cutting workpiece. The manual's first action is: “Rotate the spindle.”