Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
There was an error writing data to the medium. The manual lists no action for this code.
The device has detected the end of a partition or medium. The manual lists no action for this code.
All 19 error codes of the Sony SDT-9000 tape drive with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
A ground fault current exceeding the programmed "GF" value has been detected, requiring manual reset and motor inspection. The manual's first action is: “A manual reset is required. Check the motor for insulation brea…
The overload relay tripped on a fault and is timing down "RD3" before restarting. The manual's first action is: “If undercurrent is not a normal condition for this installation, check for broken shafts, broken belts, …
The unit failed to start and displays alternate codes for single phasing or low voltage. The manual's first action is: “Display alternates "SP", "ub", or "Lo" with the "DISPLAY / PROGRAM" switch parameter value.”
The voltage inputs are reverse phased, requiring phase swapping to correct. The manual's first action is: “If this is the initial start up, swap any two of the leads connected to "L1", "L2", or "L3" on the Motor Mento…
A high temperature has been detected by the Zem-I/O-NET system. The manual's first action is: “Check the motor for problems and the PTC connections on the ZEM-I/O-NET.”
A stop command was issued remotely from an external source. The manual lists no action for this code.
The incoming phases have been reversed, which may cause the motor to run backward upon startup. The manual lists no action for this code.
A low voltage condition exists and the unit has failed to start. The manual's first action is: “Display alternates "SP", "ub", or "Lo" with the "DISPLAY / PROGRAM" switch parameter value.”
The unit tripped due to a ground fault condition. The manual lists no action for this code.
The unit tripped due to contactor failure, despite not being single phased by incoming voltage. The manual's first action is: “Check for damaged contacts or loose wiring.”
The unit tripped on undercurrent and requires manual reset as per "#RU" setting. The manual's first action is: “Check the system for problems that would produce a loss of load like a broken belt or a pump that is out …
The unit tripped from current unbalance or failed to start due to unbalanced voltage. The manual's first action is: “Display alternates "SP", "ub", or "Lo" with the "DISPLAY / PROGRAM" switch parameter value.”