Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The manual feedrate switch is set to "0" during jog or dry run mode, or there's a short circuit in the signal wire or sequence program error. The manual's first action is: “Set the switch to a value other than "0" to …
The rapid traverse override switch is set to "0". The manual's first action is: “Cancel the error by setting the "RAPID TRAVERSE OVERRIDE" switch to a value other than "0".”
The cutting feed override switch is set to "0". The manual's first action is: “Set the switch to a value other than "0" to cancel the error.”
An attempt was made to start with duplicated operation modes, or a duplicate mode was selected during operation. The manual's first action is: “Restart after selecting the operation mode.”
Operation was attempted without selecting an operation mode or mode cancellation occurred during operation. The manual's first action is: “Restart after selecting the operation mode.”
The automatic operation mode changed during active operation to another mode. The manual's first action is: “Return to the original automatic operation mode, and restart.”
An external interlock function is active, and one axis has entered the interlocked state. The manual's first action is: “Cancel the interlock signal.”
A block stopped due to a single block stop signal turning ON. The manual's first action is: “Restarting will cause one block to be executed and then the block will stop. Canceling the single block stop signal and star…
Automatic operation was paused because an automatic stop signal turned ON. The manual's first action is: “The operation can be restarted by canceling the automatic operation stop signal.”
The over-regeneration alarm has reached 80% of its threshold level. The manual lists no action for this code.
An external emergency stop signal was received, indicating that 24V is not applied to the CN23 connector. The manual lists no action for this code.
A 25ms power interruption occurred without dropping main circuit voltage, so no alarm triggers. The manual's first action is: “NR”
The power supply is frequently regenerating at its maximum capacity limit. The manual lists no action for this code.
An emergency stop command was received from the NC system. The manual lists no action for this code.
A parameter has been set beyond its allowable range and will remain unchanged. The manual lists no action for this code.