Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
A skip command was issued while radius compensation is active, which is not permitted. The manual's first action is: “Designate a radius compensation cancel command (G40), or remove the skip command.”
A signal was turned on or off illegally during a D-commanded deceleration area. The manual's first action is: “Reconsider the program.”
The H code was not designated before the automatic tool length measurement command. The manual's first action is: “Designate the H code before the automatic tool length measurement command block.”
The H code and the automatic tool length measurement command were issued in the same block, which is not allowed. The manual's first action is: “Designate the H code before the automatic tool length measurement comman…
More than one axis or no axis was specified for automatic tool length measurement. The manual's first action is: “Designate only one axis.”
The skip speed has been set to zero, which is not allowed during operation. The manual's first action is: “Designate the skip speed.”
A multi-step skip command was issued but no such specifications exist in the program. The manual's first action is: “Check the specifications.”
The machine detected that a skip command was issued without any valid specifications for it. The manual's first action is: “Check the specifications.”
No auto TLM means that an automatic tool length measurement command was executed without any such specification being set in the program. The manual's first action is: “Check the specifications.”
No dataserver operation occurs when data server operations were attempted without any data server operation specifications being defined. The manual's first action is: “Check the specifications.”
No IC card operation means that an IC card operation was attempted without any specifications for it in the program. The manual's first action is: “Check the specifications.”
No FLD operation occurs when an FLD (floppy disk) operation was attempted without any such specification being set. The manual's first action is: “Check the specifications.”
No disk operation means that a disk operation was attempted without any disk operation specifications being defined in the program. The manual's first action is: “Check the specifications.”
No Computer Link B occurs when the system attempts to use computer link B without any specifications being set for it. The manual's first action is: “Check the specifications.”
No Computer Link A occurs when the system attempts to use computer link A without any specifications being set for it. The manual's first action is: “Check the specifications.”